![Campbell TX312 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/campbell/tx312/tx312_instruction-manual_3794250038.webp)
TX312 Transmitter
TABLE 5.2-7. Error Codes
Error Codes:
Hex Decimal
0x00 00
No
error
0x01 01
Illegal
command
0x02 02
Command
rejected
0x03
03
Illegal checksum or too much data
0x04
04
Time out or too little data
0x05 05
Illegal
parameter
0x06
06
Transmit buffer overflow
0x10
16
Message abort due to PLL
0x11
17
Message abort due to GPS
0x12
18
Message abort due to power supply – internal 16 volt – RF
0x13 19
Software
fault
0x14 20
Failsafe
fault
0x15
21
GPS time sync fault
0x16
22
SWR fault – transmission antenna connection
0x19
25
Internal RF power supply failure
See Section 5.1.2.4 for more information.
5.2.5.6 P127, Command 5: Clear TX312 Error Registers
Clear error registers of TX312. Requires one input location.
TABLE 5.2-8. P127 Command 5: Clear Error Registers
In Loc
Contents
1 Result
Code
Result code of 0 indicates success. Command 5 is used to erase all errors from
the error registers of the TX312.
5.2.5.7 P127, Command 6: Return TX312 to on-line mode.
Command 6 is used to return the TX312 to online mode. Typically used after
a forced random transmission. The TX312 has an off-line time-out of one
hour.
TABLE 5.2-9. P127 Command 6: Force On-line Mode
In Loc Contents
1 Result
code
Result code of 0 indicates success.
5.2.6 Edlog Programming Examples
Edlog instruction 126 is used to copy data from the datalogger final storage
area to the TX312 data buffer.
32
Содержание TX312
Страница 14: ...TX312 Transmitter FIGURE 3 2 TX312 Connectors FIGURE 3 3 DCP Enclosure 8...
Страница 44: ...This is a blank page...
Страница 46: ...This is a blank page...
Страница 48: ...This is a blank page...
Страница 66: ...Appendix D RAWS 7 Data Format D 18 This is a blank page...
Страница 70: ...Appendix E GOES DCS Transmit Frequencies E 4 This is a blank page...
Страница 93: ...Appendix H GOES Radio Set Certification H 1...
Страница 94: ......
Страница 95: ......