![Campbell TX312 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/campbell/tx312/tx312_instruction-manual_3794250025.webp)
TX312 Transmitter
TABLE 5.1-3. GoesStatus Command 2: Read Last Message Status
Index Contents
1
Command Result Code
2
Message type: Self-timed or Random
3
Size of message in bytes
4
Forward power in tenths of watts
5
Reflected power in tenths of watts
6
Power supply voltage under full load, in tenths of volts
7
GPS acquisition time in tens of seconds
8
Oscillator drift (signed, hundreds of Hz)
9 Latitude
degrees
10 Latitude
minutes
11 Latitude
seconds
12 Longitude
degrees
13 Longitude
minutes
14 Longitude
seconds.
5.1.2.4 GoesStatus Read Error Register
Example:
Public Errors(10)
GoesStatus(Errors(), 4)
Command 4 (Read Error Register) is used to return the total number of errors
that have occurred, and codes describing the last four errors. When the
command that caused the error is listed as 31, the error is an internal fault.
Otherwise the error is just a communication error.
TABLE 5.1-4. GoesStatus Command 4: Read TX312 Error Registers
Index Contents
1 Result
Code
2
Number of Errors
3
Command that Caused the Error
4 Error
Code
5
Command that Caused the Error
6 Error
Code
7
Command that Caused the Error
8 Error
Code
9
Command that Caused the Error
10 Error
Code
19
Содержание TX312
Страница 14: ...TX312 Transmitter FIGURE 3 2 TX312 Connectors FIGURE 3 3 DCP Enclosure 8...
Страница 44: ...This is a blank page...
Страница 46: ...This is a blank page...
Страница 48: ...This is a blank page...
Страница 66: ...Appendix D RAWS 7 Data Format D 18 This is a blank page...
Страница 70: ...Appendix E GOES DCS Transmit Frequencies E 4 This is a blank page...
Страница 93: ...Appendix H GOES Radio Set Certification H 1...
Страница 94: ......
Страница 95: ......