TDR100
6: TDR100 Measurement (P119)
1: 00
SDM
Address
2: 0
La/L
3: 1108
MMMP Mux & Probe Selection
4: 4
Waveform
Averaging
5: 1
Vp
6: 250
Points
7: 9.5
Cable
Length
(meters)
8: 5
Window
Length
(meters)
9: .3
Probe
Length
(meters)
10: .085
Probe
Offset
(meters)
11: 17
Loc [ WC_1101 ]
12: 1138
Mult
13: -0.1758 Offset
;Switch the level 1 SDMX50 to Channel 2 and measure the 7 probes
;(channels 1 through 7) on the Level 2 multiplexer that is connected to channel 2
;of the level 1 mux (apparent cable length to probe 10 meters):
7: TDR100 Measurement (P119)
1: 00
SDM
Address
2: 0
La/L
3: 2107
MMMP Mux & Probe Selection
4: 4
Waveform
Averaging
5: 1
Vp
6: 250
Points
7: 9.5
Cable
Length
(meters)
8: 5
Window
Length
(meters)
9: .3
Probe
Length
(meters)
10: .085
Probe
Offset
(meters)
11: 25
Loc [ WC_2101 ]
12: 1138
Mult
13: -0.1758 Offset
;Switch the level 1 SDMX50 to Channel 2, the level 2 SDMX50s to Channel 8 and
;measure the 8 probes (channels 1 through 8) on the Level 3 SDMX50
;(apparent cable length to probe 10 meters):
8: TDR100 Measurement (P119)
1: 00
SDM
Address
2: 0
La/L
3: 2818
MMMP Mux & Probe Selection
4: 4
Waveform
Averaging
5: 1
Vp
6: 250
Points
7: 25.0
Cable
Length
(meters)
8: 5
Window
Length
(meters)
9: .3
Probe
Length
(meters)
10: .085
Probe
Offset
(meters)
11: 32
Loc [ WC_2811 ]
12: 1138
Mult
13: -0.1758 Offset
48