NOTE:
Most Campbell Scientific devices come from the factory with a default PakBus address
of 1. For this reason, it is best not to assign PakBus address 1 to any device in the
network. Then, if a new device with default settings is added to the system, it will not
create a conflict.
7. Apply to save your changes.
7.2 Add stand-alone repeater to
LoggerNet
Enter the stand-alone repeater into the
LoggerNet
Setup screen. Add a pbRouter device with the
PakBus address of the RF407-series radio in the PakBus Address field. If the repeater is the first
hop from
LoggerNet
, it should always be shown in the network map. This will force routes to go
through the repeater. If the repeater is further down the network, it may still be helpful to display
it in the network map. However, it does not force routes to go through the repeater.
RF407-Series Spread Spectrum Radio
20