K-1
Appendix K. RF401/RF411 Pass/Fail
Tests
This appendix describes a method to functionally test RF401/RF411 system
components including:
•
PC COM port
•
SC12 serial cable
•
RF401/RF411
•
RF401/RF411 Antenna
Hardware/Software Required
PC with one available COM port
Terminal Program (HyperTerminal
TM
or Procomm
TM
)
Two RF401/RF411s
Two SC12 serial cables
¼ wave OMNI antenna (CSI Item # 14310)
Two power supplies rated 12 Volts, 1 Amp
(recommend AC adapter Item # 15966 and any 12 V battery pack
with Field Power Cable Item # 14291)
The following descriptions tell how to build an RF401/RF411 loop-back
test system. Recommendations are given as to where to place the
system to avoid rf-reflections (see TESTING ¼ Wave Antenna footnote
2
in this appendix). The basic parts of the system are:
1) PC running a terminal program and a serial cable from PC COM
port to base RF401/RF411
2) Base RF401/RF411
3) Remote RF401/RF411 with RS-232 port jumper wire between TX
(pin 2) and RX (pin 3) for data loop-back.
Build the RF401/RF411 test system in the order shown:
1) TESTING SC12 CABLE and PC COM PORT
2) TESTING RF401/RF411s
3) TESTING ANTENNAS
Label components of the system “known-good” as they pass the test.
TESTING SC12 CABLE and PC COM PORT
(1) Run a terminal program such as HyperTerminal
TM
or Procomm
TM
(a) Baud rate: 9600
(b) Data, Parity, Stop Bits: 8-N-1
(c) Flow control: none
(d) Emulation: TTY
(e) ASCII
(f) COM1 (or any available COM port)
Содержание RF401
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 16: ...Table of Contents vi...
Страница 56: ...Appendix A Part 15 FCC Compliance Warning A 2...
Страница 76: ...Appendix D Setting Up RF401 to CR206 X Communications D 10...
Страница 84: ...Appendix F Non PakBus Example Configurations F 6 FIGURE F 2 PC208W Datalogger Generic Dial String...
Страница 94: ...Appendix H Distance vs Antenna Gain Terrain and Other Factors H 8...
Страница 98: ...Appendix I Phone to RF401 Series I 4 FIGURE I 2 Phone base configuration...
Страница 99: ...Appendix I Phone to RF401 Series I 5 FIGURE I 3 Enter the base site s phone number...
Страница 114: ...Appendix K RF401 RF411 Pass Fail Tests K 8...
Страница 124: ...Appendix L RF401 RF411 Average Current Drain Calculations L 10...
Страница 129: ......