Appendix I. Phone to RF400 Series
I-2
c.
Phone Modem
1)
Baud Rate – 9600
2)
Modem Pick List – per PC’s phone modem
3)
Extra Response Time – 2000 ms
d.
Datalogger – Dialed Using Phone # at Base site
RF400 CONFIGURATION
a.
Base RF400
1)
Active Interface: “COM2xx to RF400”
2)
AT Command (Attention) Character: “-“
3)
All other settings: defaults
b.
Remote RF400 – leave all settings: defaults
Note: If there is a neighboring RF400 network, you should change
the Hopping Sequence of base and remote RF400s to a new setting to
avoid interference (see Section 5.3.1 for method to detect neighboring
network).
3.
POINT-TO-MULTIPOINT COMMUNICATIONS
PC-Modem ------------ COM210-PS512M-RF400 ------------ RF400-DL1
(null-modem)
------------
RF400-DL2
LoggerNet SETUP
a.
Setup:
ComPort_1
PhoneBase
PhoneRemote
RF400
RF400Remote
CR10X
RF400Remote_2
CR10X_2
b.
ComPort_1 – default settings
c.
PhoneBase
1)
Maximum Baud Rate – 9600
2)
Modem Pick List – per PC’s phone modem
3)
Extra Response Time – 0 s
d.
PhoneRemote – input base site’s phone number
e.
RF400 – make Attention Character: “-“ ; leave the rest defaults
f.
RF400Remote – make Radio Address: “1“ ; leave the rest defaults
g.
RF400Remote_2 – make Radio Address: “2“ ; leave the rest defaults
h.
Dataloggers – default settings, schedule collections as desired
Содержание RF400
Страница 4: ...This is a blank page...
Страница 7: ...RF400 Table of Contents iii K 1 900 MHz Gain Antenna Test Distances K 6 L 1 Advanced Setup Menu L 1...
Страница 8: ...RF400 Table of Contents iv This is a blank page...
Страница 40: ...This is a blank page...
Страница 44: ...Appendix B Setup Menu B 4 This is a blank page...
Страница 54: ...This is a blank page...
Страница 64: ...Appendix H Distance vs Antenna Gain Terrain and Other Factors H 8 This is a blank page...
Страница 72: ...Appendix J Monitor CSAT3 via RF400 Series J 2 This is a blank page...
Страница 88: ...Appendix L RF400 RF410 Average Current Drain Calculations L 10 This is a blank page...
Страница 89: ...This is a blank page...