Raven100 CDMA AirLink Cellular Modem
compare them to the template from the Campbell Scientific website).
See Figure 7-1. The existing value is under the column heading
‘Value’ and the value we recommend is under the column ‘New
Value’.
b.
If the serial out has increased, the modem attempted to connect to the
datalogger, but the response from the datalogger did not make it back
to the modem (check your cable connections and interfaces).
c.
If both values have incremented, the modem and datalogger are
communicating the connection is not being established (try adding
extra response time to the LoggerNet Setup). If you have changed the
baud rate remotely, the modem will need to be reset for this setting to
take affect. This can be done by pressing the ‘Reset’ button on the
Wireless Ace screen. You must have established a connection first
before you do this.
FIGURE 7-2. Wireless Ace status page showing communications
with modem.