background image

PS150/CH150 12 V Charging Regulators 

15 

6.2  Maximum Power Point Tracking 

The current and power versus voltage for a 70 W solar panel are illustrated in 

FIGURE 

6-1

As can be seen from the figure, a Maximum Power Point of 

operation exists for solar panels. Adjusting the load on the solar panel so it 

operates at this Maximum Power Point is referred to as Maximum Power Point 

Tracking (MPPT). MPPT is beneficial when insufficient power is available 

from the charge source, which is the case during current limited charging. The 

somewhat noisy charging current and voltage during the initial current limited 

charging stage is due to the MPPT algorithm of the PS150/CH150 searching 

for the maximum power point of the associated solar panel.  

 

FIGURE 6-1.  70 W solar panel I – V and power characteristics 

7.  A100 Null Modem Adapter 

The A100 adapter has two 9-pin 

CS I/O

 ports with a null modem between 

them. The ports are used to connect two 9-pin devices (such as modems or RF 

radios) that would normally be connected to the 

CS I/O

 port of a Campbell 

Scientific data logger. The charger supplies 12 VDC and 5 VDC to the 

appropriate pins on the connector for powering the connected devices. This 

functionality is required in a station where a data logger will not be present, 

such as a phone-to-RF base station. The A100 cannot be used as a null modem 

between two RS-232 devices. 

The A100 mounts directly to the CH150 to receive power. Align the green 

connector inside the A100 (FIGURE 

7-1

) with the receptacle on the CH150 

and press the A100 into place (FIGURE 

7-2

). Secure the A100 by tightening 

the screw on the front of the A100 (FIGURE 

7-3

). 

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

0

0.9

1.8

2.7

3.6

4.5

0

10

20

30

40

50

60

70

Voltage (Volts)

C

ur

re

nt

 (A

m

ps

)

Po

w

er

 (W

at

ts)

4.5

0

I

m

70

0

P

m

21

0

Vc

m

Содержание PS150

Страница 1: ...PS150 CH150 12 V Charging Regulators Revision 06 2020 Copyright 2000 2020 Campbell Scientific Inc...

Страница 2: ...4 1 Specifications 10 4 2 Battery Packs 11 4 3 Charging Sources 11 5 Operational Overview 13 6 Charging Details 14 6 1 Charging Algorithm 14 6 2 Maximum Power Point Tracking 15 7 A100 Null Modem Adap...

Страница 3: ...Table of Contents ii 6 1 70 W solar panel I V and power characteristics 15 7 1 A100 connector 16 7 2 Installing the A100 16 7 3 A100 mounting screw 17 8 1 A105 adapter 17...

Страница 4: ...compatible with the A100 null modem adapter and the A105 adapter for additional 12 V output terminals The A100 Null Modem Adapter connects and powers two Campbell Scientific peripherals via two CS I...

Страница 5: ...ry reversal protection which is catastrophic for most chargers ESD and surge protection are incorporated on all inputs and outputs of the PS150 CH150 2 Precautions and Tips Risk of electric shock Use...

Страница 6: ...number of useful cycles available from the battery1 Leaving a lead acid battery in a discharged state for prolonged periods of time results in the undesirable growth of large sulfate crystals sulfati...

Страница 7: ...PS150 CH150 12 V Charging Regulators 4 FIGURE 3 1 The PS150 connected to a CR1000 and AC power FIGURE 3 2 The PS150 connected to a CR1000 and solar panel...

Страница 8: ...nnecting a battery The CH PS150 allow both solar and AC power to be simultaneously connected Toggle the power supply switch to Off before connecting power to the power supply The switch on the CH PS15...

Страница 9: ...e check the input voltages coming in to the charger regulator with a volt meter AC Input Voltage 14 to 24 VAC RMS DC Input Voltage 15 to 40 VDC Exceeding the voltages listed above will damage the powe...

Страница 10: ...done to minimize any damage that could occur if the power supply should get loose from its mounts inside the enclosure during shipment The battery will NOT be plugged into the PS150 This is done to mi...

Страница 11: ...0 lid off Plug the battery wire into the battery wire terminal indicated in FIGURE 3 7 This connector is polarized and will only allow the mating connector to be plugged in one way Push the connector...

Страница 12: ...lug Connector marked G 3 4 Turn On the Charging Source Turn on the power going to the charging source or uncover the solar panel The green Charge LED will flash approximately once a second if all inco...

Страница 13: ...re Range2 40 to 60 C Power Out 12 terminals Voltage Unregulated 12 V from Battery 4 65 A solid state circuit breaker Quiescent Current No Charge Source Present 160 A at 13 7 VDC No Battery Connected 9...

Страница 14: ...nown effects on the life of the battery Battery life is shortened if the battery is allowed to discharge below 11 5 V 4 3 Charging Sources Campbell Scientific Solar Panels SP10 SP20 SP50 Peak Power 10...

Страница 15: ...use Approval ETL Listed for US and Canada Both of the recommended chargers have DC voltage output which can be used on either the CHARGE CHARGE or SOLAR G terminal blocks Maximum input charging curren...

Страница 16: ...ic Charging power for the PS150 CH150 is typically supplied by an unregulated solar panel AC AC transformer or AC DC converter The CHARGE CHARGE terminals are connected to a full bridge rectifier acco...

Страница 17: ...urce that can deliver up to 3 6 A current without damage The SOLAR G terminals are optimal for solar panels because of the high current charging capability when solar resources are available A Maximum...

Страница 18: ...A100 Null Modem Adapter The A100 adapter has two 9 pin CS I O ports with a null modem between them The ports are used to connect two 9 pin devices such as modems or RF radios that would normally be c...

Страница 19: ...PS150 CH150 12 V Charging Regulators 16 FIGURE 7 1 A100 connector FIGURE 7 2 Installing the A100 Connector...

Страница 20: ...harging regulator The extra terminals make it easier to wire multiple continuously powered 12 VDC devices to the power supply The A105 shares the same form factor as the A100 Refer to Section 7 A100 N...

Страница 21: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more informat...

Страница 22: ...shipping container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Prod...

Страница 23: ...ng on or around tripods and towers Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use o...

Страница 24: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: