NL115 Ethernet and CompactFlash
®
Module
4
4.2.2
Step 2: LoggerNet Setup
The next step is to run LoggerNet and configure it to connect to the datalogger via
the Ethernet port.
a.
In LoggerNet’s Setup Screen, press Add Root and choose IPPort. Input the
datalogger’s IP address and port number. The IP address and port number
are input on the same line separated by a colon. (The datalogger’s default
port number is 6785. It can be changed using Device Configuration Utility
or by modifying its value in the Status Table.)
b.
Add a PakBus port and set the desired baud rate.
c.
Add the datalogger (CR1000 or CR3000). Input the PakBus address of the
datalogger.
Figure 4-3. LoggerNet setup
4.2.3
Step 3: Connect
You are now ready to connect to your datalogger using the LoggerNet Connect
Screen.
Datalogger program transfer, table-data display, and data collection are now
possible.