Campbell Met One 034B Скачать руководство пользователя страница 11

 

Met One 034B Wind Set 

1.  Introduction 

The 034B Wind Set combines a 3-cup anemometer and vane into a single 

integrated package to measure wind speed and direction. It is cabled for use 

with our dataloggers, and can provide measurements for a variety of 

applications.  

This manual provides information only for CRBasic dataloggers. 

It is also compatible with most of our retired Edlog dataloggers. 

For Edlog datalogger support, see an older manual at 

www.campbellsci.com/old-manuals

  or contact Campbell 

Scientific.  

2.  Precautions 

 

READ AND UNDERSTAND the 

Safety

 section at the front of this 

manual. 

 

The 034B is a precision instrument. Please handle it with care.  

 

If the 034B is to be installed at heights over 6 feet, be familiar with tower 

safety and follow safe tower climbing procedures. 

 

Danger—Use extreme care when working near overhead electrical wires. 

Check for overhead wires before mounting the 034B or before raising a 

tower. 

 

The set screw holes must be covered with labels to prevent corrosion and 

assure the warranty. 

 

The black outer jacket of the cable is Santoprene® rubber. This compound 

was chosen for its resistance to temperature extremes, moisture, and UV 

degradation. However, this jacket will support combustion in air. It is rated 

as slow burning when tested according to U.L. 94 H.B. and will pass 

FMVSS302. Local fire codes may preclude its use inside buildings. 

3.  Initial Inspection 

Upon receipt of the 034B, inspect the packaging and contents for damage. File 

damage claims with the shipping company. Immediately check package contents 

against the shipping documentation (see Section 

3.1

Ships With List

 

(p. 2)

)

Contact Campbell Scientific about any discrepancies. 

The model number and cable length are printed on a label at the connection end 

of the cable. Check this information against the shipping documents to ensure 

the expected product and cable length are received. 

NOTE 

Содержание Met One 034B

Страница 1: ...INSTRUCTION MANUAL Met One 034B Wind Set Revision 9 16 C o p y r i g h t 1 9 8 0 2 0 1 6 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European marke...

Страница 6: ......

Страница 7: ...ore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit...

Страница 8: ......

Страница 9: ...tion 5 6 3 General Specifications 6 7 Installation 6 7 1 Siting 6 7 2 Mounting Options 6 7 2 1 Mount to a Crossarm 6 7 2 2 Mount to Top of Tripod 9 7 3 Wiring 9 7 4 Programming 10 7 4 1 Wind Speed 10...

Страница 10: ...orth to East of Magnetic North C 2 C 2 Declination Angles True North to West of Magnetic North C 3 C 3 Magnetic Declination at 2012 5 degrees relative to true north positive is east C 3 D 1 034B poten...

Страница 11: ...ical wires Check for overhead wires before mounting the 034B or before raising a tower The set screw holes must be covered with labels to prevent corrosion and assure the warranty The black outer jack...

Страница 12: ...e 1 Sensor cable of user specified length 4 QuickStart Short Cut is an easy way to program your datalogger to measure the 034B and assign datalogger wiring terminals Short Cut is available as a downlo...

Страница 13: ...the Available Sensors and Devices list select the Sensors Meteorological Wind Speed Direction folder Select 034A 034B Wind Speed Direction Sensor Click to move the selection to the Selected device wi...

Страница 14: ...diagram in step 4 check the output of the sensor in the datalogger support software data display to make sure it is making reasonable measurements 5 Overview The 034B Wind Set is used to measure hori...

Страница 15: ...om cws900 for more information 6 Specifications Features Designed for continuous long term unattended operation in adverse conditions Constructed of light weight aluminum Compatible with Campbell Scie...

Страница 16: ...ing the height of the sensors above the roof should be at least 1 5 times the height of the building See Section 9 References p 13 for a list of references that discuss siting wind speed and direction...

Страница 17: ...URE 7 1 8 Insert the 034B into the aluminum bushing provided with the sensor see FIGURE 7 1 9 Align the hole in the bushing with that in the 034B base and replace the screw see FIGURE 7 1 10 Insert th...

Страница 18: ...et One 034B Wind Set 8 FIGURE 7 1 034B mounted on a crossarm using a 17953 Nu Rail Crossover Fitting FIGURE 7 2 CM200 Series Crossarm with CM220 Right Angle Mounting Bracket CM220 CM200 Series Crossar...

Страница 19: ...e Colour Wire Function and Datalogger Connection Wire Colour Wire Function Datalogger Connection Terminal Red WS Signal U configured for pulse input1 P pulse input or P_SW pulse switch closure input B...

Страница 20: ...ely with Short Cut If your data acquisition needs are more complex the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program...

Страница 21: ...ple Program p B 1 for example Excitation voltages range codes and multipliers for our dataloggers are listed in TABLE 7 3 The multiplier value converts the sensor s millivolt output to degrees Appendi...

Страница 22: ...beginning of this document for the procedure of returning the sensor to Campbell Scientific for bearing replacement 2 Years Replace the wind vane potentiometer and bearings Refer to the Assistance pa...

Страница 23: ...losure Hertz and multiplier and offset parameters for the pulse count instruction are correct for the datalogger type 9 References The following references give detailed information on siting wind spe...

Страница 24: ...Met One 034B Wind Set 14...

Страница 25: ...the program and exit Short Cut Make note of the file name used when saving the Short Cut program 2 Open CRBasic Editor 3 Click File Open Assuming the default paths were used when Short Cut was instal...

Страница 26: ......

Страница 27: ...bles and Units Public Batt_Volt Public WS_ms Public WindDir Units Batt_Volt Volts Units WS_ms meters second Units WindDir degrees Define Data Tables DataTable Table1 True 1 DataInterval 0 60 Min 10 Wi...

Страница 28: ......

Страница 29: ...sily corrected by adding or subtracting the difference between the two readings as explained below Maps are always drawn in relation to the true north pole and ordnance survey maps will normally show...

Страница 30: ...asily done with two people one person to aim and adjust the sensor and a second person to observe the wind direction readings from the datalogger Ideally use RS232 Direct Link to laptop computer to vi...

Страница 31: ...lower orientation fitting band clamp on the Wind Sentry arm so that it can be rotated by hand Do not loosen the upper clamp 6 While holding the vane in the correct true north position at all times ca...

Страница 32: ......

Страница 33: ...ll Scientific has a 9 53 k fixed resistor and a variable resistor on the excitation line The variable resistor is adjusted by the manufacturer so its resistance plus the 9 53 k resistor equals the res...

Страница 34: ...ua Apinag s nbr 2018 Perdizes CEP 01258 00 S o Paulo SP BRASIL www campbellsci com br vendas campbellsci com br Campbell Scientific Canada Corp 14532 131 Avenue NW Edmonton AB T5L 4X4 CANADA www campb...

Отзывы: