Mount the Pedestrian Station
1. Route the four conductor cable from the 1 1/8” hole through the pole into the pedestrian
signal head for connection to the SPI.
2. Route the four conductor cable and the pedestrian input circuit wires through the
terminal back plate with nipple installed.
3. Connect four conductor cable and traffic control cabinet field input wires to barrier screw
terminals on the back of the base station. See Table 1 page 10.
4. Place a small bead of silicone around the flange for the back plate and tighten screws.
5. Use an anti-seize compound on all screws.
6. Place the pedestrian station on the pole and fasten using two ¼ - 20 FHP screws.
Ensure a snug fit.
7. Place the adapter plate and / or sign using provided hardware.
8. Base Station Hardware kits:
(5x7) Adapter Plate, Sign Hardware, and Base Staion Mounting Hardware
2ea. 8-32 X 1 ¾” FHP Screws (AP)
2ea. 8-32 X 1 ¾” PHP Screws (Sign – AP top holes)
2ea. 8-32 X 1/4" PHP Screws (Sign – bottom holes)
2ea. ¼ - 20 x 1“ FHP Screws (Standard mounting bolts)
(9x12 & 9x15)
Adapter Plate, Sign Hardware, and Base Station Mounting Hardware
4ea. 8-32 X 1 ¾” FHP Screws (AP)
4ea. 8-32 X ¼” PHP Screws (Sign)
2ea. ¼ - 20 x 1“ FHP Screws (Standard mounting holes)
(400 A) Base Station Mounting Hardware
2ea. ¼ - 20 x 1“ FHP Screws (Standard mounting bolts)