![Campbell GPS16X-HVS Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/campbell/gps16x-hvs/gps16x-hvs_user-manual_489135037.webp)
Appendix B. CR23X Wiring and Programming
B-9
start P15 just before the GPS16X-HVS sends the $GPGGA string. If the PPS
signal pulls C8 high while the datalogger is in the middle of executing an
instruction, it may not be able to run subroutine 98 before the $GPGGA string has
started, which will cause the datalogger to miss the data string. Turning on the
data buffering may remedy the problem. Lengthening the serial time-out to allow
P15 to execute for 2 cycles of NMEA output may help. Otherwise the SDM-SIO4
may be required or the datalogger program will need to be simplified.
The datalogger will not pick up valid data until the GPS16X-HVS has a valid GPS
fix, except during a GPS16X-HVS warm start where time can be read before
position is known. Don’t spend a lot of time trouble shooting a phantom problem
just because the GPS receiver does not have a valid GPS fix.