ET107 Weather Station
56
2.
Replace the connector cover. The tab at the top of the connector cover
slides into the opening on the back of the crossarm. Ensure that all cables
and connector caps are under the cover before tightening the Phillips screw
at the bottom of the cover. Make sure that all cables coming out of the top
right of the connector cover are not being pinched.
FIGURE 5-48. Connector cover in place
3.
Tighten the wire ties holding the cables to the wire tie harness and clip off
excess ties (FIGURE
).
5.10.2 Sealing and Desiccating the Enclosure
The ET107 enclosure is supplied with two desiccant packs. The desiccant
maintains a low humidity in the enclosure to minimize the chance of
condensation on the instrumentation. Desiccant should be changed when the
internal enclosure humidity sensor measures 50% or higher. Install the
desiccant as shown in FIGURE
. Keep unused desiccant tightly sealed in
an airtight container.
Place the desiccant into the enclosure after all other weather
station installation steps have been completed.
NOTE