DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND 

TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, 

ANTENNAS, ETC

. FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, 

TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS 

INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE. TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS. 

CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE 

EQUIPMENT PRIOR TO PERFORMING ANY WORK. 
Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed. Do not exceed design limits. Be familiar and 

comply with all instructions provided in product manuals. Manuals are available at www.campbellsci.com. You are responsible for conformance with 

governing codes and regulations, including safety regulations, and the integrity and location of structures or land to which towers, tripods, and any 

attachments are attached. Installation sites should be evaluated and approved by a qualified engineer. If questions or concerns arise regarding installation, 

use, or maintenance of tripods, towers, attachments, or electrical connections, consult with a licensed and qualified engineer or electrician. 
General 

 

Protect from over-voltage. 

 

Protect electrical equipment from water.  

 

Protect from electrostatic discharge (ESD). 

 

Protect from lightning. 

 

Prior to performing site or installation work, obtain required approvals and permits. Comply with all 

governing structure-height regulations. 

 

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and any 

attachments to tripods and towers. The use of licensed and qualified contractors is highly recommended. 

 

Read all applicable instructions carefully and understand procedures thoroughly before beginning work. 

 

Wear a

 hardhat 

and

 eye protection

, and take 

other appropriate safety precautions

 while working on or 

around tripods and towers.

 

 

Do not climb

 tripods or towers at any time, and prohibit climbing by other persons. Take reasonable 

precautions to secure tripod and tower sites from trespassers. 

 

Use only manufacturer recommended parts, materials, and tools. 

Utility and Electrical 

 

You can be killed

 or sustain serious bodily injury if the tripod, tower, or attachments you are installing, 

constructing, using, or maintaining, or a tool, stake, or anchor, come in 

contact with

 

overhead or 

underground utility lines

 

Maintain a distance of at least one-and-one-half times structure height, 6 meters (20 feet), or the distance 

required by applicable law, 

whichever is greater

, between overhead utility lines and the structure (tripod, 

tower, attachments, or tools). 

 

Prior to performing site or installation work, inform all utility companies and have all underground utilities 

marked. 

 

Comply with all electrical codes. Electrical equipment and related grounding devices should be installed by a 

licensed and qualified electrician. 

 

Only use power sources approved for use in the country of installation to power Campbell Scientific devices. 

Elevated Work and Weather 

 

Exercise extreme caution when performing elevated work. 

 

Use appropriate equipment and safety practices. 

 

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-essential 

personnel. Take precautions to prevent elevated tools and objects from dropping. 

 

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc. 

Maintenance 

 

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, frayed cables, 

loose cable clamps, cable tightness, etc. and take necessary corrective actions. 

 

Periodically (at least yearly) check electrical ground connections. 

Internal Battery 

 

Be aware of fire, explosion, and severe-burn hazards. 

 

Misuse or improper installation of the internal lithium battery can cause severe injury. 

 

Do not recharge, disassemble, heat above 100 °C (212 °F), solder directly to the cell, incinerate, or expose 

contents to water. Dispose of spent batteries properly. 

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE 

CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF 

TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, 

ETC. 

Содержание DCDC18R

Страница 1: ...DCDC18R Boost Regulator Revision 10 2021 Copyright 1999 2021 Campbell Scientific Inc ...

Страница 2: ...n of this document Use the PDF reader bookmarks tab for links to specific sections 1 General Description 1 2 Specifications 1 3 Installation 2 4 Grounding 3 Figures 1 1 DCDC18R 1 3 1 Wiring for DCDC18R 2 3 2 DCDC18R on CR5000 3 4 1 Schematic of Charging and Grounding Circuitry 4 ...

Страница 3: ...to the 17 VDC minimum required to charge the batteries in the CR3000 CR5000 or CR23X LA bases It can be conveniently bolted onto the side of the LA base next to the charger input FIGURE 1 1 DCDC18R Input Voltage 11 to 16 VDC Output Voltage 18 V 5 Quiescent Current 4 mA Maximum Output Current 1 Amp Maximum Input Current 2 25 Amps Power Conversion Efficiency 80 to 90 Temperature Range 40 to 60 C ...

Страница 4: ...rference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The slow start boost regulator typically starts to work at a supply voltage of about 10 volts Supply voltages below 10 volts pass directly to V out through 2 Schottky diodes dropping the vol...

Страница 5: ...its transient protection to work CONNECTIONS TO THE CHARGING INPUT DO NOT PROPERLY GROUND THE DATALOGGER The Ground connection should be made at the grounding lug on the wiring panel A full wave bridge rectifier is included on the CR3000 CR5000 and CR23X LA bases and the PS100 This creates a diode drop 0 7 V between the datalogger ground and the return side of the charging input FIGURE 4 1 If the ...

Страница 6: ...the ground lug However unwanted ground loops that induce single ended measurement offsets will be generated if the terminals and the return side of the charging input are tied together because the return current to the DCDC18R will flow through the terminals FIGURE 4 1 Schematic of Charging and Grounding Circuitry ...

Страница 7: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more information CAMPBELL SCIENTIFIC EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Campbell Scientific hereby disclaims to the fullest extent allowe...

Страница 8: ...tion or Repair Reference number contact your CAMPBELL SCIENTIFIC regional office Please write the issued number clearly on the outside of the shipping container and ship as directed For all returns the customer must provide a Statement of Product Cleanliness and Decontamination or Declaration of Hazardous Material and Decontamination form and comply with the requirements specified in it The form i...

Страница 9: ...e and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use only manufacturer recommended parts materials and tools Utility and Electrical You can be killed or sustain serious bodily injury if the tripod tower or attachments you are installing constructing using or maintaining or a tool stake or anchor come in contact with overhead or ...

Страница 10: ...info campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India 91 11 46500481 482 info campbellsci in www campbellsci in South Africa Location Phone Email Website Stellenbosch South Africa 27 21 8809960 sales campbellsci co za www campbellsci co za Spain Locati...

Отзывы: