Safety

 

DANGER 

 MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON 

OR AROUND 

TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, 

CROSSARMS, ENCLOSURES, ANTENNAS, ETC

.  FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, 

INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED 
WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS INJURY, PROPERTY DAMAGE, AND 
PRODUCT FAILURE.  TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS.  CHECK WITH YOUR 
ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE 
EQUIPMENT PRIOR TO PERFORMING ANY WORK. 

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed.  Do not 
exceed design limits.  Be familiar and comply with all instructions provided in product manuals.  Manuals are 
available at www.campbellsci.eu or by telep44(0) 1509 828 888 (UK).  You are responsible for conformance 
with governing codes and regulations, including safety regulations, and the integrity and location of structures or land 
to which towers, tripods, and any attachments are attached.  Installation sites should be evaluated and approved by a 
qualified engineer.  If questions or concerns arise regarding installation, use, or maintenance of tripods, towers, 
attachments, or electrical connections, consult with a licensed and qualified engineer or electrician. 

General 

Prior to performing site or installation work, obtain required approvals and permits. Comply with all

governing structure-height regulations, such as those of the FAA in the USA.

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and any

attachments to tripods and towers.  The use of licensed and qualified contractors is highly recommended.

Read all applicable instructions carefully and understand procedures thoroughly before beginning work.

Wear a hardhat and eye protection, and take other appropriate safety precautions while working on or

around tripods and towers.

Do not climb tripods or towers at any time, and prohibit climbing by other persons. Take reasonable

precautions to secure tripod and tower sites from trespassers.

Use only manufacturer recommended parts, materials, and tools.

Utility and Electrical 

You can be killed or sustain serious bodily injury if the tripod, tower, or attachments you are installing,

constructing, using, or maintaining, or a tool, stake, or anchor, come in contact with overhead or

underground utility lines.

Maintain a distance of at least one-and-one-half times structure height, or 20 feet, or the distance

required by applicable law, whichever is greater, between overhead utility lines and the structure (tripod,

tower, attachments, or tools).

Prior to performing site or installation work, inform all utility companies and have all underground utilities

marked.

Comply with all electrical codes.  Electrical equipment and related grounding devices should be installed

by a licensed and qualified electrician.

Elevated Work and Weather 

Exercise extreme caution when performing elevated work.

Use appropriate equipment and safety practices.

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-essential

personnel.  Take precautions to prevent elevated tools and objects from dropping.

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc.

Maintenance 

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, frayed cables,

loose cable clamps, cable tightness, etc. and take necessary corrective actions.

Periodically (at least yearly) check electrical ground connections.

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL 
SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER 
INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS 
SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC. 

Содержание CS705

Страница 1: ...Revision 01 2022 Copyright 1997 2022 Campbell Scientific CSL I D 1196...

Страница 2: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 3: ...cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some...

Страница 4: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 5: ...OT recommended 3 4 2 Tipping bucket compatibility 3 5 Specifications 3 6 Installation 4 6 1 Siting 4 6 2 Mounting pole 5 6 3 CM270 installation 6 6 4 CS705 to tipping bucket installation procedure 10...

Страница 6: ...choose a site that is easily accessible throughout the winter l Wear safety glasses and rubber or neoprene gloves while handling and pouring antifreeze l Campbell Scientific strongly recommends using...

Страница 7: ...ually flows through the overflow tube and is measured by the tipping bucket gauge A delay of minutes is expected for liquid precipitation so long as a minimum volume of water 0 03 inches is reached A...

Страница 8: ...der that allows it to nest within the 8 inch orifice of the TE525WS rain gauge The CS705 cannot be directly used with other Campbell Scientific rain gauges However the TE525 and TE525MM gauges can be...

Страница 9: ...atch of winter precipitation by antifreeze based gauges is directly related to wind speed Errors due to wind can be minimized by properly siting the gauge The preferred gauge site is in a natural well...

Страница 10: ...the tripod or tower CM300 series poles can be embedded directly into a concrete foundation FIGURE 6 2 p 5 or used with a pedestal kit Campbell Scientific offers a j bolt pedestal kit a short leg 23 in...

Страница 11: ...socket wrench l Long 2 Phillips Screwdriver Remove manufacturer s mounting hardware 1 Remove the three feet mounted on the bottom of the rain gauge 2 Remove the side bracket but keep the screws 3 Plac...

Страница 12: ...rommets 3 Place the V shaped plate onto the bottom plate The V shaped plate s legs should be on the levelling springs and the bubble level should be next to the pole mounting hardware 4 Use two bolts...

Страница 13: ...FIGURE 6 4 Exploded view of the CM270 Mounting Bracket Kit FIGURE 6 5 Two views of an assembled CM270 CS705 Snowfall Adapter 8...

Страница 14: ...on the drain funnel should fit over the round bolt heads 3 Place the mounting bracket on the funnel Line up the three holes in the mounting bracket with the three small holes on the funnel When posit...

Страница 15: ...lock washer and wingnut See FIGURE 6 7 p 10 3 Tighten the assembly onto the pipe while ensuring that nothing is blocking the top of the rain gauge 4 Adjust the two bolts on the levelling springs unti...

Страница 16: ...ge mount FIGURE 6 8 CS705 mounted to pole using the CM270 Mounting Kit 1 Take one of the black bands supplied with the CS705 and stretch over the TE525WS funnel see FIGURE 6 8 p 11 and FIGURE 6 9 p 12...

Страница 17: ...environmentally safe oil to the antifreeze reservoir This oil prevents the antifreeze solution from evaporating The oil should cover the entire liquid surface Some unscented baby oils lightweight min...

Страница 18: ...verflow tube is free from ice or debris and remove any debris from the catch orifice If the slot in the overflow tube becomes plugged the overflow tube may create a siphon and draw down the antifreeze...

Страница 19: ...ispose of all spent antifreeze solution in accordance with local state and federal regulations The CS705 is recommended only for use during winter It should be removed cleaned and carefully stored aft...

Страница 20: ...6148 CHEMICAL NAME AND SYNONYMS CAMPBELL SCIENTIFIC CS705 ANTIFREEZE TRADE NAME AND SYNONYMS Same as above CHEMICAL FAMILY Solvent blend FORMULA Mixture DATE OF PREPARATION 09 26 97 REVISION DATE N A...

Страница 21: ...APPEARANCE AND ODOR Clear colorless liquid mild odor 5 Section IV HMIS Rating HEALTH 2 FLAMMABILITY 4 REACTIVITY 0 0 Minimal 1 Slight 2 Moderate 3 Serious 4 Severe 6 Section V Figure and Explosion Ha...

Страница 22: ...disturbances of vision tingling numbness and shooting pains in the hands and forearms INGESTION May cause nausea abdominal pain vomiting headache dizziness shortness of breath weakness fatigue leg cra...

Страница 23: ...own to adversely effect the CNS of the fetus producing a collection of effects which together constitute the fetal alcohol syndrome Symptoms include mental and physical retardation learning disorders...

Страница 24: ...ASE MATERIAL IS RELEASED OR SPILLED Contain spill provide adequate ventilation keep people away EXTINGUISH ALL IGNITION SOURCES keep material out of public waters use dry absorbent on small spills WAS...

Страница 25: ...absorbed through skin Avoid breathing vapor Causes eye irritation DO NOT get on skin on clothing May cause drowsiness dizziness Avoid contact w eyes May cause heart muscle damage Keep container closed...

Страница 26: ...XII SARA Title III This product contains the following toxic chemical that is claimed as a trade secret but disclosed as an upper bound concentration to comply with the reporting requirements of Sect...

Страница 27: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: