Table 8-2: Extended SDI-12 commands for the CS475A
Command name
Command
format
Sensor
response
Configuration by sensor
Write Number of
Measurements
for the
M2!
Command
Returns: New
number of
measurements
for the
M2!
command
aXWNM2=nn!
aD0!
atttn
a+nn+ee
Change the number of
measurements completed for the
M2!
Response
nnn: number of measurements
(max is 60)
ee: error code
Read Number of
Measurements
for the
M2!
Command
Returns: Number
of measurements
for the
M2!
command
aXRNM2!
aD0!
atttn
a+nn+ee
Pull the number of measurements
completed for the
M2!
Response
from memory
nn: number of measurements
(max is 60)
ee: error code
Write Number of
Measurements
for the
M3!
Command
Returns: New
number of
measurements
for the
M3!
command
aXWNM3=nn!
aD0!
atttn
a+nn+ee
Change the number of
measurements completed for the
M3!
Response
nn: number of measurements
(max is 15)
ee: error code
CS475A Radar Water Level Sensor