CS475, CS476, and CS477 Radar Water Level Sensor
13
CS475
CS476/CS477
FIGURE 7-1. Polarization markings (see TABLE
descriptions)
TABLE 7-3. Description of Polarization Markings Labels
Sensor
Description
1
CS475
Polarization marks are designated by
the mounting loop screws.
2
CS476/CS477
Polarization mark is machine-tooled.
After mounting, you can rotate the housing up to 350° to simplify access to the
conduit entry and terminal compartment. Proceed as follows to rotate the
housing to the desired position:
1.
Loosen the set screw on the housing.
2.
Rotate the housing as desired.
3.
Tighten the set screw.