CS300 and CS301 Pyranometers
8
7.3
Wiring to the Datalogger
500 to 600
typical
Single-Ended
Analogue
Input
Ground/
⏚
Ground/
⏚
FIGURE 7-1. Schematic diagram
Connections to Campbell Scientific dataloggers are given in TABLE
When
Short Cut
is used to create the datalogger program, connect the sensor to
the terminals shown in the wiring diagram created by
Short Cut
.
TABLE 7-1. Wire Colour, Function, and Datalogger Connection
CS300
Wire
Colour
CS301
Wire
Colour
Wire
Function
Datalogger Connection Terminal
Red
White
Signal
U
configured for single-ended
analogue input
1
,
SE
(single-ended,
analogue-voltage input)
Black
Black
Signal
Reference
⏚
(analogue ground)
Clear
Clear
Shield
⏚
(analogue ground)
1
U
terminals are automatically configured by the measurement instruction.
7.4
Programming
Short Cut
is the best source for up-to-date datalogger programming code.
If data acquisition requirements are simple, a datalogger program can probably
be created and maintained exclusively with
Short Cut
. If the data acquisition
needs are more complex, the files that
Short Cut
creates are a great source for
programming code to start a new program or add to an existing custom
program.
Short Cut
cannot edit programs after they are imported and
edited in
CRBasic Editor
.
A
Short Cut
tutorial is available in Section
. To import
Short
Cut
code into
CRBasic Editor
to create or add to a customized program, follow
NOTE