Campbell CS300 Скачать руководство пользователя страница 11

 

CS300 and CS301 Pyranometers 

1.

 

Introduction 

The CS300 and CS301 measure total sun and sky solar radiation for solar, 
agricultural, meteorological, and hydrological applications. Their spectral 
range of 360 to 1120 nanometers encompasses most of the shortwave radiation 
that reaches the Earth surface. These pyranometers connect directly to our 
dataloggers. Their output can be measured by all of our dataloggers.  

The CS301 replaced the CS300 in August 2018. The CS301 has a stainless 
steel connector, a removable cable, different wire colours, and a serial number 
of 60051 or above. Both sensors are manufactured by Apogee Instruments. 

This manual provides information only for CRBasic dataloggers. 
For  retired  Edlog  datalogger  support,  you  can  access  a  retired 
manual at 

www.campbellsci.com/old-manuals

. 

2.

 

Precautions 

 

READ AND UNDERSTAND the 

Safety

 section at the front of this 

manual.  

 

Carefully open the shipping package ensuring to not damage or cut the 
cable jacket. If the cable is damaged, consult with Campbell Scientific. 

 

Remove the green cap after installing the sensor. Save this cap for 
shipping or storing the sensor. 

 

Handle the sensor carefully when cleaning. Be careful not to scratch the 
surface of the sensor. 

 

The black outer jacket of the cable is Santoprene®

 

rubber. This compound 

was chosen for its resistance to temperature extremes, moisture, and UV 
degradation. However, this jacket will support combustion in air. It is rated 
as slow burning when tested according to U.L. 94 H.B. and will pass 
FMVSS302. Local fire codes may preclude its use inside buildings. 

3.

 

Initial Inspection 

 

Upon receipt of the pyranometer, inspect the packaging and contents for 
damage. File damage claims with the shipping company. 

4.

 

QuickStart 

A video that describes datalogger programming using 

Short Cut

 is available at: 

www.campbellsci.eu/videos/cr1000x-datalogger-getting-started-program-part-
3

Short Cut

 is an easy way to program the datalogger to measure the 

pyranometer and assign datalogger wiring terminals. 

Short Cut

 is available as a 

download on 

www.campbellsci.

eu

. It is included in installations of 

LoggerNet

PC200W

PC400

, or 

RTDAQ

NOTE 

Содержание CS300

Страница 1: ...CS300 and CS301 Pyranometers Revision 9 18 Copyright 1994 2018 Campbell Scientific...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European marke...

Страница 6: ......

Страница 7: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 8: ......

Страница 9: ...ion 5 7 1 Siting 5 7 2 Mounting to an Instrument Mount 5 7 2 1 Required Tools 5 7 2 2 Mounting Procedure 5 7 3 Wiring to the Datalogger 8 7 4 Programming 8 7 4 1 Total Solar Radiation 9 8 Maintenance...

Страница 10: ...ers Required for Average Flux and Total Flux Density in SI and English Units 9 B 1 Wiring for Example Programs B 1 CRBasic Examples B 1 CR1000X Program Measuring the CS300 or CS301 B 1 B 2 CR6 Program...

Страница 11: ...If the cable is damaged consult with Campbell Scientific Remove the green cap after installing the sensor Save this cap for shipping or storing the sensor Handle the sensor carefully when cleaning Be...

Страница 12: ...cate the sensor in the Sensors Meteorological Solar Radiation folder Double click CS301 Pyranometer Default units are kW m2 for flux density and mJ m2 for total flux These can be changed by clicking t...

Страница 13: ...Send the program to the datalogger if the datalogger is connected to the computer 9 If the sensor is connected to the datalogger check the output of the sensor in the data display in LoggerNet PC400...

Страница 14: ...iation This negative signal is caused by noise passing through the photo diode Often negative values are set to zero in the datalogger program 6 Specifications Features Designed for continuous long te...

Страница 15: ...unted at heights of 3 m or less are easier to level and clean 7 2 Mounting to an Instrument Mount 7 2 1 Required Tools Tools required for installation on a tripod or tower Small and medium Phillips sc...

Страница 16: ...es and tightening the nuts Secure the 015ARM to the mast by tightening the U bolt nuts 3 Place the pyranometer in the centre of the pyranometer levelling base CM225 Stand CM200 Series Crossarm U bolt...

Страница 17: ...ion Check that the pyranometer is still correctly levelled and adjust as necessary 7 Route the sensor cable along the underside of the crossarm or 015ARM mounting arm to the tripod tower and to the in...

Страница 18: ...nalogue voltage input Black Black Signal Reference analogue ground Clear Clear Shield analogue ground 1 U terminals are automatically configured by the measurement instruction 7 4 Programming Short Cu...

Страница 19: ...m 2 t 0 005 Total cal cm 2 min 1 0 005 1 434 Average cal cm 2 t 0 005 0 0239 Total t datalogger execution interval in seconds Joules Cal ratio 4 184 J cal Possible sources of electrical noise include...

Страница 20: ...the sensor head and cannot be serviced Symptom Incorrect solar radiation 1 Make sure the top surface of the sensor head is clean and that the sensor is properly levelled 2 Verify that the range code...

Страница 21: ...reate the Short Cut program following the procedure in Section 4 QuickStart p 1 Finish the program On the Advanced tab click the CRBasic Editor button The program opens in CRBasic with the name noname...

Страница 22: ......

Страница 23: ...Description CR1000X CR6 Red White Signal SE 1 U1 Black Black Signal Ground Clear Clear Shield B 1 CR1000X Program CRBasic Example B 1 CR1000X Program Measuring the CS300 or CS301 CR1000X Declare Cons...

Страница 24: ...and Units Public BattV Public PTemp_C Public SlrW Public SlrMJ Units BattV Volts Units PTemp_C Deg C Units SlrW W m 2 Units SlrMJ MJ m 2 Define Data Tables DataTable Hourly True 1 DataInterval 0 60 Mi...

Страница 25: ...Appendix B Example Programs B 3 Convert mV to W m SlrW SlrW 5 0 Call Data Tables and Store Data CallTable Hourly CallTable Daily NextScan EndProg...

Страница 26: ...W Edmonton Alberta T5L 4X4 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www c...

Отзывы: