PLEASE READ FIRST 

About this manual 

Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North 
American  market. Some spellings, weights and measures may reflect this origin. 

Some useful conversion factors: 

Area:

   1 in

2

 (square inch) = 645 mm

2

 

Length:    

1 in. (inch) = 25.4 mm 

1 ft (foot) = 304.8 mm 
1 yard = 0.914 m 
1 mile = 1.609 km 

Mass:

  

1 oz. (ounce) = 28.35 g 
1 lb (pound weight) = 0.454 kg 

Pressure:

 

1 psi (lb/in

2

) = 68.95 mb 

Volume:

 

1 UK pint = 568.3 ml 
1 UK gallon = 4.546 litres 
1 US gallon = 3.785 litres 

In addition, while most of the information in the manual is correct for all countries, certain information 
is specific to the North American market and so may not be applicable to European users.  

Differences include the U.S standard external power supply details where some information (for 
example the AC transformer input voltage) will not be applicable for British/European use. 

Please note, 

however, that when a power supply adapter is ordered it will be suitable for use in your country. 

Reference to some radio transmitters, digital cell phones and aerials may also not be applicable 
according to your locality. 

Some brackets, shields and enclosure options, including wiring, are not sold as standard items in the 
European market; in some cases alternatives are offered. Details of the alternatives will be covered in 
separate manuals. 

Part numbers prefixed with a “#” symbol are special order parts for use with non-EU variants or for 
special installations. Please quote the full part number with the # when ordering. 

Recycling information 

At the end of this product’s life it should not be put in commercial or domestic refuse but 
sent for recycling.  Any batteries contained within the product or used during the 
products life should be removed from the product and also be sent to an appropriate 
recycling facility. 

Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases 
arrange collection and the correct disposal of it, although charges may apply for some 
items or territories.  

For further advice or support, please contact Campbell Scientific Ltd, or your local agent. 

Campbell Scientific Ltd, 80 Hathern Road, Shepshed, Loughborough, LE12 9GX, 

UK Tel: +44 (0) 1509 601141    Fax: +44 (0) 1509 

270924

  

Email: [email protected] 

www.campbellsci.co.uk 

Содержание CS300

Страница 1: ...CS300 and CS301 Pyranometers Revision 9 18 Copyright 1994 2018 Campbell Scientific...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European marke...

Страница 6: ......

Страница 7: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 8: ......

Страница 9: ...ion 5 7 1 Siting 5 7 2 Mounting to an Instrument Mount 5 7 2 1 Required Tools 5 7 2 2 Mounting Procedure 5 7 3 Wiring to the Datalogger 8 7 4 Programming 8 7 4 1 Total Solar Radiation 9 8 Maintenance...

Страница 10: ...ers Required for Average Flux and Total Flux Density in SI and English Units 9 B 1 Wiring for Example Programs B 1 CRBasic Examples B 1 CR1000X Program Measuring the CS300 or CS301 B 1 B 2 CR6 Program...

Страница 11: ...If the cable is damaged consult with Campbell Scientific Remove the green cap after installing the sensor Save this cap for shipping or storing the sensor Handle the sensor carefully when cleaning Be...

Страница 12: ...cate the sensor in the Sensors Meteorological Solar Radiation folder Double click CS301 Pyranometer Default units are kW m2 for flux density and mJ m2 for total flux These can be changed by clicking t...

Страница 13: ...Send the program to the datalogger if the datalogger is connected to the computer 9 If the sensor is connected to the datalogger check the output of the sensor in the data display in LoggerNet PC400...

Страница 14: ...iation This negative signal is caused by noise passing through the photo diode Often negative values are set to zero in the datalogger program 6 Specifications Features Designed for continuous long te...

Страница 15: ...unted at heights of 3 m or less are easier to level and clean 7 2 Mounting to an Instrument Mount 7 2 1 Required Tools Tools required for installation on a tripod or tower Small and medium Phillips sc...

Страница 16: ...es and tightening the nuts Secure the 015ARM to the mast by tightening the U bolt nuts 3 Place the pyranometer in the centre of the pyranometer levelling base CM225 Stand CM200 Series Crossarm U bolt...

Страница 17: ...ion Check that the pyranometer is still correctly levelled and adjust as necessary 7 Route the sensor cable along the underside of the crossarm or 015ARM mounting arm to the tripod tower and to the in...

Страница 18: ...nalogue voltage input Black Black Signal Reference analogue ground Clear Clear Shield analogue ground 1 U terminals are automatically configured by the measurement instruction 7 4 Programming Short Cu...

Страница 19: ...m 2 t 0 005 Total cal cm 2 min 1 0 005 1 434 Average cal cm 2 t 0 005 0 0239 Total t datalogger execution interval in seconds Joules Cal ratio 4 184 J cal Possible sources of electrical noise include...

Страница 20: ...the sensor head and cannot be serviced Symptom Incorrect solar radiation 1 Make sure the top surface of the sensor head is clean and that the sensor is properly levelled 2 Verify that the range code...

Страница 21: ...reate the Short Cut program following the procedure in Section 4 QuickStart p 1 Finish the program On the Advanced tab click the CRBasic Editor button The program opens in CRBasic with the name noname...

Страница 22: ......

Страница 23: ...Description CR1000X CR6 Red White Signal SE 1 U1 Black Black Signal Ground Clear Clear Shield B 1 CR1000X Program CRBasic Example B 1 CR1000X Program Measuring the CS300 or CS301 CR1000X Declare Cons...

Страница 24: ...and Units Public BattV Public PTemp_C Public SlrW Public SlrMJ Units BattV Volts Units PTemp_C Deg C Units SlrW W m 2 Units SlrMJ MJ m 2 Define Data Tables DataTable Hourly True 1 DataInterval 0 60 Mi...

Страница 25: ...Appendix B Example Programs B 3 Convert mV to W m SlrW SlrW 5 0 Call Data Tables and Store Data CallTable Hourly CallTable Daily NextScan EndProg...