CS230/CS231 Temperature Profiler
10
same data logger control or
U
terminal if they have different SDI-12 addresses.
If changing the SDI-12 addresses, Campbell Scientific recommends starting the
readdressing process with the largest temperature sensor address to avoid
duplicate addresses. TABLE
provides the SDI-12 addresses and positions.
Use the default SDI-12 addresses when possible. Inadvertently
giving multiple sensors the same SDI-12 address will prevent the
sensors from communicating. Use the
aA{!
command, where
a
is
the affected address to reset the affected sensors to their factory
configured address value.
TABLE 8-2. SDI-12 Addresses and Positions
Numeric Set Uppercase Set
Lowercase Set
1 / 1
A / 10
a / 36
2 / 2
B / 11
b / 37
3 / 3
C / 12
c / 38
4 / 4
D / 13
d / 39
5 / 5
E / 14
e / 40
6 / 6
F / 15
f / 41
7 / 7
G / 16
g / 42
8 / 8
H / 17
h / 43
9 / 9
I / 18
i / 44
J / 19
j / 45
K / 20
k / 46
L / 21
l / 47
M / 22
m / 48
N / 23
n / 49
O / 24
o / 50
P / 25
p / 51
Q / 26
q / 52
R / 27
r / 53
S / 28
s / 54
T / 29
t / 55
U / 30
u / 56
V / 31
v / 57
W / 32
w / 58
X / 33
x / 59
Y / 34
y / 60
Z / 35
a / 61
{ – reset to factory address
NOTE