CS120A and CS125 Visibility and Present Weather Sensors
42
Data returned by the GET command
GET returned data
Example
Description
0x02
(1)
STX
Sensor ID
User Alarm 1 Set
User Alarm 1 Active (0 = less than)
User Alarm 1 Distance
User Alarm 2 Set
User Alarm 2 Active
User Alarm 2 Distance
Serial Baud Rate
Sensor serial number (read only)
Visibility Units
Message interval
Polling or Continuous modes
Message Format
RS-232 or RS-485 serial communications enabled
Averaging Period
Sample timing
Dew heater override
Hood heater override
Dirty window compensation
CRC-16 checking on received commands
Sensor power down voltage
Relative humidity threshold
XXXX
Checksum
0x04
(1)
EOT
0x0D
(1)
Carriage return
0x0A
Line feed
(1) These values are shown in hexadecimal format not ASCII.