Campbell CS120A Скачать руководство пользователя страница 3

 

 

Guarantee 

This equipment is guaranteed against defects in materials and workmanship. 
This guarantee applies for twelve months from date of delivery. We will repair 
or replace products which prove to be defective during the guarantee period 
provided they are returned to us prepaid. The guarantee will not apply to: 

 

Equipment which has been modified or altered in any way without the 
written permission of Campbell Scientific  

 

Batteries  

 

Any product which has been subjected to misuse, neglect, acts of God or 
damage in transit. 

Campbell Scientific will return guaranteed equipment by surface carrier 
prepaid. Campbell Scientific will not reimburse the claimant for costs incurred 
in removing and/or reinstalling equipment. This guarantee and the Company’s 
obligation thereunder is in lieu of all other guarantees, expressed or implied, 
including those of suitability and fitness for a particular purpose. Campbell 
Scientific is not liable for consequential damage. 

Please inform us before returning equipment and obtain a Repair Reference 
Number whether the repair is under guarantee or not. Please state the faults as 
clearly as possible, and if the product is out of the guarantee period it should 
be accompanied by a purchase order.  Quotations for repairs can be given on 
request. It is the policy of Campbell Scientific to protect the health of its 
employees and provide a safe working environment, in support of this policy a 
“Declaration of Hazardous Material and Decontamination” form will be 
issued for completion. 

When returning equipment, the Repair Reference Number must be clearly 
marked on the outside of the package. Complete the “Declaration of 
Hazardous Material and Decontamination” form and ensure a completed copy 
is returned with your goods. Please note your Repair may not be processed if 
you do not include a copy of this form and Campbell Scientific Ltd reserves 
the right to return goods at the customers’ expense. 

Note that goods sent air freight are subject to Customs clearance fees which 
Campbell Scientific will charge to customers. In many cases, these charges are 
greater than the cost of the repair. 

 

 

 
 

Campbell Scientific Ltd, 

80 Hathern Road,  

Shepshed, Loughborough, LE12 9GX, UK 

Tel: +44 (0) 1509 601141 

Fax: +44 (0) 1509 601091 

Email: [email protected] 

www.campbellsci.co.uk 

Содержание CS120A

Страница 1: ...CS120A Power Supply Enclosure Issued 29 10 14 Copyright 2012 Campbell Scientific Ltd CSL 949 INSTALLATION GUIDE ...

Страница 2: ......

Страница 3: ...ether the repair is under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be given on request It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment in support of this policy a Declaration of Hazardo...

Страница 4: ......

Страница 5: ...nt for recycling Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases arrange collection and the correct disposal of it although charges may apply for some items or territories For further advice or su...

Страница 6: ......

Страница 7: ...fore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use only manufacturer recommended parts materials and tools Utility and Electrical You can be ...

Страница 8: ......

Страница 9: ...or links to specific sections 1 Installation instructions for an enclosure that includes a mains powered CS120A Power Supply 1 1 1 Required knowledge 1 1 2 Preparation and initial checks 1 1 3 Wiring into the enclosure 2 1 4 General use and access to the enclosure 6 Figures 1 General View 3 2 Mains Connections 4 3 DC Connections 5 ...

Страница 10: ......

Страница 11: ...ribe how to do this and precautions for the use of the system after installation The CS120A power supply is sold as a kit that is normally fitted inside a standard Campbell Scientific environmental enclosure often with other components such as a datalogger or communications interfaces The layout of each enclosure can therefore vary but the wiring details for the AC supply are standard The power su...

Страница 12: ...so requires correct connection of the Live and Neutral conductors make sure these are identified and wired correctly at the power source For outside installations the power source should be fitted with its own or system wide earth leakage breaker also known as an RCD 1 3 Wiring into the enclosure Fig 1 shows a typical enclosure fitted with a similar power supply to that used for the CS120A The sup...

Страница 13: ...Installation Guide 3 A clip is fitted to the chassis plate below the terminal block to allow the mains cable to be fixed with a cable tie to give some strain relief Fig 1 General View ...

Страница 14: ... a secondary block of terminals labelled 24V DC and 12 V DC Fig 3 The 24V DC from the AC fed power supply is the output used to power the hood heaters of the CS120A The 24V supply is often also used to provide charging power to a backup power supply for the microprocessor DSP of the CS120A such as a PS100 or PS200 which may be installed in the enclosure That supply may also be used to power a data...

Страница 15: ...onnected to the 12V feed for extended periods without the main supply connected otherwise the CS120A may shutdown and or the battery in the PS100 PS200 may be damaged Please refer to the CS120A manual for more details of the low battery shutdown settings Fig 3 DC Connections WARNING ...

Страница 16: ...uding details of how to isolate power to the enclosure 1 4 General use and access to the enclosure The enclosure is supplied with and should always be fitted with a padlock to stop unqualified personnel opening the enclosure The enclosure should be left locked at all times If acceptable for the system operation it is best practice to isolate the mains power supply to the enclosure before opening t...

Страница 17: ......

Страница 18: ...ientific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc info campbellsci cc Campbell Scientific Ltd CSL 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France 3 Avenue de la Division Leclerc 92160 ANTONY FRANCE www campbellsci fr info campbellsci fr...

Отзывы: