User Guide
31
Once a calibration is finished changes are immediate, but factory
calibrations can be restored if needed using Option `(2)’ in the
calibration menu. The disk constants however remain as the last
disk used.
Option (4) gives the systems information menu containing useful information such
as temperature and system alarms.
Menu 4: The system information menu
If either of the dirty window alarms are set it is recommended you follow the
cleaning section of this manual (Section 18).
If there is a flash error or signature error it is recommended that you contact
Campbell Scientific.
The sensor power down voltage shown before the supply voltage is only available
if the sensor is running firmware version 4 or later and only functional for sensors
with serial number greater than E1029.
NOTE
CS120A INFORMATION - MENU 4
ID 0
S/N 1009
OS version: CS120Av7
Alarm Value
- Last visibility reading: - 5017M
- Overall system status: 0 No faults
- Emitter dirty window alarm: 0 -4%
- Emitter internal temperature: 0 33.3
- Detector dirty window alarm: 0 0%
- Detector internal temperature: 0 28.9
- Detector DC light saturation: 0 -
- Hood heater temperature: 0 24.9
- CS120A Calibrator Serial No: - 1000
- CS120A Calibrator Constant: - 30.5
- Calibration value Fac offset: - -0.136
- Calibration value Fac scale: - 0.02724
- Calibration value Cal offset: - -0.136
- Calibration value Cal scale: - 0.02724
- Signature fault: 0 -
- Flash write errors: 0 0
- Flash read errors: 0 0
- Supply voltage: <9.0V 12.5V
(8) Get debug
(9) Refresh
(0) Return to main menu
Содержание CS120A
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 23: ...User Guide 13...
Страница 24: ...CS120A Visibility Sensor 14...
Страница 25: ...User Guide 15...
Страница 50: ...CS120A Visibility Sensor A 2...
Страница 52: ...CS120A Visibility Sensor B 2...