CS120A and CS125 Visibility and Present Weather Sensors
43
These selections output more than one variable
(1)
These options will only be available if you’re using a CS125
(2)
Only outputs a valid final message value when a CS215 temperature and humidity probe is connected
Description of the custom message bits
Bit
Description
8000
Reserved
4000
Reserved
2000
Humidity (%)
1000
Temperature (Degrees C)
0800
NWS code
0400
METAR code
0200
SYNOP code
0100
Generic SYNOP
0080
Accumulation
0040
Intensity
0020
Particle count
0010
Sensor serial number
0008
Dirty windows values
0004
System alarms
0002
User alarms
0001
Averaging duration
The HEX value is the sum of all the required fields.
The following example shows the calculation of the HEX value to use a
MSGSET message to set a CS125 to output temperature, SYNOP code, sensor
serial number, dirty windows values and system alarms.
Description of the custom message bits
Bit
Description
8000
Reserved
4000
Reserved
2000
Humidity (%)
1000
Temperature (Degrees C)
0800
NWS code
(3)
0400
METAR code
0200
SYNOP code
(3)
0100
Generic SYNOP
(3)
0080
Accumulation
(3)
0040
Intensity
(3)
0020
Particle count
(3)