process for every single-hop CRVW3 device in your network. Perform a clock check on
each station as it is added. Click Apply in each case.
20. To add CRVW3 devices that are reached through a CRVW3 repeater station, click on the
CRVW3 device that has been configured as a repeater station and click Add. Choose
CRVWSeries from the data logger list and click Close. Now the CRVW3 device appears as a
child device of the CRVW3 repeater. This will instruct
LoggerNet
to route through the
CRVW3 repeater to communicate with the CRVW3 child device. Rename the device,
configure it and click Apply. Multiple CRVW3 child devices can be added to any CRVW3
repeater/parent. Using the tab screens, configure these devices in the same way as the
other CRVW3 devices.
9.3 Connecting to CRVW3 stations
Use the Connect Screen to connect to each CRVW3 station and confirm that it is communicating
and operating correctly.
For more information, see:
www.campbellsci.com/videos/connect-window-tutorial
.
1. From the Main category of the
LoggerNet
toolbar click Connect
. The Stations list shows
all CRVW3 devices that have been defined on your network map.
2. Select a station from the list on the left and click Connect
.
3. The Stations list shows all CRVW3 devices that have been defined on your network map.
4. Select a station from the list on the left and click Connect
.
CRVW3 3-Channel Vibrating-Wire Data Logger