background image

 

                 PRINTED IN U.S.A.

 

 
 

 

SOFTWARE UPGRADE INSTRUCTIONS 

 

INSTALLING SOFTWARE RELEASE 9V309-01E IN THE 
80115 DATA RECORDER MODEL  
(FOR MODEL 3000 GCP) 
 

 
 

May 2002 (Revised December 2008)

 

 

DOCUMENT NO.  SIG-00-01-17

 

VERSION C

 

 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

Safetran Systems Corporation, California Division 
10655 7th Street, Cucamonga, California  91730 

 

1-800-793-SAFE 

 
 

Copyright © 2002 Safetran Systems Corporation 

 
 

Summary of Contents for 3000 GCP

Page 1: ...V309 01E IN THE 80115 DATA RECORDER MODEL FOR MODEL 3000 GCP May 2002 Revised December 2008 DOCUMENT NO SIG 00 01 17 VERSION C Safetran Systems Corporation California Division 10655 7th Street Cucamonga California 91730 1 800 793 SAFE Copyright 2002 Safetran Systems Corporation ...

Page 2: ...ined in any translation of manual or product information from its original official released version in English and shall not be liable for any losses caused by such reliance on the accuracy reliability or timeliness of such information Any person or entity who relies on translated information does so at his or her own risk WARRANTY INFORMATION SAFETRAN SYSTEMS CORPORATION warranty policy is as st...

Page 3: ...t software version also appears as the second message displayed during event printout To observe the sticker it is necessary to remove the Data recorder module from the 3000 GCP case as follows Step 1 Set the 3000 GCP case POWER switch to the OFF position WARNING INTERRUPTING GCP POWER WILL ACTIVATE THE CROSSING TAKE NECESSARY PRECAUTIONS TO PROTECT PEDESTRIANS AND VEHICLES IN THE IMMEDIATE AREA S...

Page 4: ... Computer DOS compatible with CD drive RS 232 cable 9 pin female to 25 pin male Safetran provided software release disk Z224 9V333 A01B Software Upgrade Instructions document number SIG 00 01 17 Version C Static shielding bag Flash PROM revision sticker F UPGRADE PROCEDURE CAUTION THIS UPDATE WILL AUTOMATICALLY CLEAR ALL RECORDED DATA FROM MEMORY Step 1 Verify that GCP POWER switch is ON 9 309 01X...

Page 5: ... hard drive for example C Safetran Step 5 Exit to DOS Windows DOS shell or Command Prompt Step 6 At the C prompt type CD name of folder example CD safetran Step 6 1 Press the Enter key Step 7 At the prompt type LOADBOOT Step 7 1 Press the Enter key The Setup screen displays see figure 3 9V309f2 10 11 01 COM1 PORT 9 PIN RS 232 CONNECTOR 80115 SERIAL PORT 25 PIN RS 232 CONNECTOR HISTORY ENTER SYSTEM...

Page 6: ...tep 8 1 Set the Recorder Module CLEAR OFF PRINT toggle switch to the CLEAR position and hold then set the MS GCP POWER switch to ON Step 8 2 Continue to hold the CLEAR OFF PRINT toggle switch in the CLEAR position until a Downloading window appears briefly within the Setup screen see figure 4 Figure 4 Boot Program Downloading Window 115f4 tif 10 12 01 115f2 tif 10 12 01 Figure 3 Data Recorder Modu...

Page 7: ...ee figure 5 Step 9 Type Y A boot reburn program Downloading window appears in the Setup screen see figure 6 At completion of the boot reburn program download the Success window displays within the Setup screen see figure 7 Figure 5 Boot Program Update Dialog Box 155f4 tif 10 12 01 Figure 6 Boot Reburn Program Download Window 155f6 tif 10 12 01 ...

Page 8: ...ys see figure 2 Step 12 Set the MS GCP POWER switch to OFF Step 12 1 Set the Recorder Module CLEAR OFF PRINT toggle switch to the CLEAR position and hold then set the MS GCP POWER switch to ON Step 12 2 Continue to hold the CLEAR OFF PRINT toggle switch in the CLEAR position until a downloading window appears briefly within the Setup screen see figure 8 155f7 tif 10 12 01 Figure 7 Boot Program Upd...

Page 9: ...pdate dialog box displays within the Setup screen see figure 9 Step 13 Type Y A setup program Downloading window appears in the Setup screen see figure 10 155f8 tif 10 12 01 Figure 8 Setup Program Download Window 155f9 tif 10 12 01 Figure 9 Setup Program Flash Memory Update Dialog Box ...

Page 10: ...ify that checksum displayed in Setup screen circled on figure 11 is identical to checksum supplied with program disk This completes application software installation Step 15 Set the 3000 GCP case POWER switch to the OFF position 155f10 tif 10 12 01 Figure 10 Setup Program Download Window 155f11 tif 10 12 01 Figure 11 Setup Program Success Window ...

Page 11: ... Step 17 Refer to figure 1 and locate flash PROM U10 9V309 Step 18 Affix a 9V309 A01E flash PROM revision sticker to flash PROM U10 as shown in figure 1 Ensure that the new revision sticker covers the old revision sticker Step 19 Return the Data Recorder Module to the proper slot in the 3000 GCP case Ensure that the module is fully seated in the edge connector Step 20 Set the 3000 GCP case POWER s...

Reviews: