Page 1: ...Operating manual Data acquisition system PWBlogg Type N6 60 ...

Page 2: ...Ballenstedt All rights reserved No section of the operating manual may be replicated or processed duplicated or distributed using electronic systems in any way print photocopy microfilm or other methods without prior written permission of the Paul Wegener GmbH Design and specifications are subject to change without notice 2 ...

Page 3: ...unting and connecting the device must only be done if there is no potentially explosive atmosphere Connecting and disconnecting the plug connectors is only permitted if there is no explosive atmosphere Unused sockets must be closed with dedicated protective caps Unplugged connectors are not permitted in hazardous areas Always remove unplugged connectors from hazardous areas Opening the case must o...

Page 4: ...er parameters 6 2 2 Error sources 7 2 3 Data communicationv 8 3 Charging the built in accumulator 9 4 Technical specifications 10 4 1 Data memory 10 4 2 Estimation of accumulator service life 11 5 Recycling batteries and old appliances 11 6 Troubleshooting 13 Paul Wegener GmbH 4 ...

Page 5: ...r The data logger has an integrated analog digital converter with high resolution which is responsible for log ging and digitizing pressure and temperature readings A microprocessor stores the readings in the integra ted memory At its highest expansion stage it can log 3 8 million readings Data logger parameterizing as well as reading and evaluating performance data is done on any PC laptop or net...

Page 6: ...erval 2 can be set from 1s optional 10ms up to 1min It will be activated once a threshold violation is recognized Threshold monitoring The data logger provides specifying thresholds and records threshold violations by means of a second sam ple rate Additional to the threshold a hysteresis can be specified Furthermore the data logger has an implemented sniff mode This mode is enabled in case alarm ...

Page 7: ...ion system 2 2 Error sources The analog signals of transducers are converted into a digital value with resolution of 8 bit 12 bit 14 bit or 16 bit The following table demonstrates the difference between resolutions by means of a 16 bar transducer The values represented in PWB Soft program or on LCD must be rounded to the defaulted number of deci mal places so that the increment between two neighbo...

Page 8: ...oped software PWB Soft provides data communucation with the data logger N6 60 Any necessary parameters on measurement are set here Fot that purpose this software provides different dialog windows Performance data evaluation can be done in tabular form or as chart ...

Page 9: ...mulator s residual capacity by means of the PC software PWB Soft To preserve the accumulator you should deactivate measurement when not needed for some time by setting measurement start ahead The ideal storage residual capacity is about 20 never store with an empty accumulator Note Depth discharge damages the accumulator permanently When falling below minimum voltage data logging will be stopped T...

Page 10: ...x 115200 Bd when reading data Power supply 7 2V lithium ion accumulator 3100 mAh 7 2V lithium battery 2100mAh optional Operating storage Temperature 20 60 C Explosion protection II 3G Ex ec ic Gc IIC T4 Gc X optional Environment 20 C Ta 60 C Electrical parameters for intrinsically safe status and counting inputs maximum values per circuit Voltage U0 9 2 V Current I0 9 3 mA Power P0 21 4 mW Capacit...

Page 11: ... are subject to particular statutory provisions Batteries rechargeable batteries and electric appliances must not be disposed with the household waste The end user is obligated to return them by the law Used electric appliances batteries and rechargeable batteries can be disposed at collecting points municipal disposal areas or by manufacturer supplier The Paul Wegener GmbH as seller of batteries ...

Page 12: ...ference resistance industrial sector EN 60079 0 2019 09 electrical equipment for potentially explosive atmospheres section 0 general requirements EN 60079 7 2016 08 potentially explosive atmospheres section 7 equipment protection by increased safety e EN 60079 11 2012 06 explosive atmosphere section 11 equipment protection by intrinsic safety i Marking as category 3 equipment for use in gas explos...

Page 13: ...een intruded into the data logger Accumulator is low Have it replaced by manufacturer Password forgotten Read out performance data send reading file to manufacturer Software does not read performance data comple tely or reports errors when reading out the data Check whether the PC data cable is properly connected Have checked by manufacturer whether moisture is intruded in the data logger accumula...

Page 14: ...Paul Wegener GmbH 14 ...

Page 15: ...15 Operating manual of data acquisition system PWBlogg ...

Page 16: ...GmbH 16 Paul Wegener GmbH Marienstraße 24 D 06493 Ballenstedt Tel Fax Internet e mail 49 0 39483 96 300 49 0 39483 96 400 www paul wegener de info paul wegener de PWB FORM 2084 EN22 Most recent emendment 16 06 2022 ...