CRVW3 3-Channel Vibrating-Wire Datalogger
26
understanding of the multiple settings that are set within
DevConfig
. For details
about this polynomial-based calculation process, refer to Appendix
Engineering Output and Calibration
(p. E-1)
.
If you wish to use a current barometric pressure reading as part of
the calculation of water height, pressure, or related measurements,
refer to Appendix
Engineering Output and Calibration
(p. E-1)
Radio, Radio Power Schedule, Radio Advanced
When using a radio option, there are some key settings on the
Radio, Radio
Power Schedule,
and
Radio Advanced
tabs that should be set. See Section
Validating Radio Connectivity in the Lab
(p. 29)
Validating CRVW3 Radio Operation
(p. 49)
, for more details about these
settings.
8.1.5.2 Managing Changes to Settings
Once you have made changes to the CRVW3’s settings, the
Apply
button at
the bottom of the
DevConfig
screen becomes active. Press
Apply
to execute
the changes on the device. The CRVW3 will be busy for up to 20 seconds to
complete the changes. During that time, you will not be able to connect to the
CRVW3. Watch the LEDs on the device to determine when the device has
completed its reconfiguration and has begun making measurements again.
Applying changes to certain CRVW3 settings may cause the
CRVW3 to reset its operating mode, change its table structure, and
can result in data being erased
. Please be certain that you have
collected all required data from the CRVW3 before making
changes to its settings. Changes to the following settings will reset
the final storage data on the CRVW3:
• Measurement Interval
• Channel Enabled
• Channel Name (when channel is enabled)
• Thermistor Enabled
• Thermistor Coefficients ABC (when changed from all zeroes
or changed to all zeroes)
• Calculate Engineering Output
• Use Baseline Offsets
• Use Ambient Pressure Correction
• Engineering Units (string setting)
• Use Digits
If you want to abandon the changes that have been made since connecting to
the CRVW3, use the
Cancel
button.
Press the
Factory Defaults
button to set all settings to their default values. It is
necessary to press
Apply
to execute these settings and place them into the
device.
Once you have used the
Settings Editor
tab to configure a device with certain
settings, the current state can be saved to a file on the PC. You can use the
Summary
button to display a summary of the current settings. Press the
Save
NOTE
NOTE