OV4. Specifications
CR9032 CPU MODULE
PROCESSORS: 180 MHz Hitachi SH-4
MEMORY: 128 Mbytes of internal SDRAM for program
and data storage. Expanded data storage with
PCMCIA type I, type II or type III cards.
SERIAL INTERFACES: RS-232
9-pin interface for computer or modem. CS I/O
9-pin interface for CSI peripherals and SDM
devices.
ETHERNET INTERFACE: 10baseT/100baseT port for
communications over a local network or the
Internet.
CR9011 POWER SUPPLY MODULE
VOLTAGE: 9.6 to 18 Vdc
TYPICAL CURRENT DRAIN: Base system with no
modules is 500 mA active; 300 mA standby.
Current drain of individual I/O modules varies.
Refer to specifications for each I/O module for
specific values. Power supply module can place
the system in standby mode by shutting off power
to the rest of the modules.
DC CHARGING: 9.6 to 18 Vdc input charges internal
batteries at up to 2 A rate. Charging circuit
includes temperature compensation.
INTERNAL BATTERIES: Sealed rechargeable with
14 Ahr (7 Ahr for the CR9000XC) capacity per
charge.
EXTERNAL BATTERIES: External 12 V batteries can
be connected.
CR9041 A/D and AMPLIFIER MODULE
A/D Conversions: 16-bit, 100 kHz
TRANSIENT PROTECTION
All analog and digital inputs and outputs use gas
discharge tubes and transient filters to protect against
high-voltage transients. Digital I/Os also have over-
voltage protection clamping.
PHYSICAL
Size
LAB ENCLOSURE:
15.75"L x 9.75"W x 8"D
(40 x 24.8 x 20.3 cm)
FIBERGLASS
ENCLOSURE:
18"L x 13.5"W x 9"D
(45.7 x 34.3 x 22.9 cm)
CR9000XC:
10"L x 11"W X 9"D
(25.4 x 27.9 x 22.9 cm)
Weight
LAB ENCLOSURE: 30 lbs including modules
(13.6 kg)
FIBERGLASS ENCLOSURE: 42 lbs including
modules (19.1 kg)
CR9000XC: 27 lbs including modules (12.3 kg)
REPLACEMENT BATTERIES: 6.4 lbs (2.9 kg)
ADDITIONAL MODULES: 1 lb each (0.5 kg)
WARRANTY
Three years against defects in materials and
workmanship.
General CR9000X & CR9000XC Specifications
We recommend that you confirm system
configuration and critical specifications with
Campbell Scientific before purchase.
Electrical specifications are valid over a -25° to +50°C range unless otherwise specified; testing over -40° to
+70°C available as an option, excluding batteries. Non-condensing environment is required. To maintain specifi-
cations, Campbell Scientific recommends recalibrating dataloggers every two years.