Appendix C. CVF4 Ventilation Unit
C-3
FIGURE C-3. CVF4 Ventilation Unit and Ships With Kit
C.3 CVF4 Installation
Siting information provided in Section
(p. 7)
, is pertinent when using
the CVF4 heater/ventilation.
1.
CVF4 heater/ventilator unit includes the heater/ventilator unit, white
cover, cable, and mounting hardware. The CVF4 is mounted to a crossarm
by using the CVF4 Mounting Stand and either the CM220 Right-Angle
Mounting Bracket or the 1-inch-by-1-inch Nu-Rail Crossover Fitting.
Refer to the Kipp & Zonen Instruction Manual if mounting the
CVF4 to a SOLYS 2 Solar Tracker or to a CM 121C Shadow Ring.
Tools required for mounting to a tripod or tower are:
•
Allen wrench supplied with the CVF4
•
8 mm (5/16-inch) open-end wrench for U-bolt nuts
•
Tape measure
•
UV-resistant wire ties
•
Side-cut pliers
•
Step ladder
NOTE