Table 7-1: CH201 measurements
Measurement
Units
Battery voltage
V
Battery current
A
Load current
A
DC In 1 voltage
V
DC In 2 voltage
V
Temperature
°C
Charge state
SDI-12 Response
RS-232 Response/
DI-12 Meaning
–1
“REGULATOR FAULT”
0
“NO CHARGE”
1
“CURRENT LIMITED”
2
“CYCLE CHARGING”
3
“FLOAT CHARGING”
Charge source
SDI-12 Response
RS-232 Response/
SDI-12 Meaning
0
“NONE”
1
"DC In 1"
2
“DC In 2”
Check battery
0 = normal
1 = check battery (battery voltage less
than 10.5 V or battery is open circuit)
Target battery voltage
V
Input voltage at maximum power
V
Battery capacity
Ah
Qloss
Ah
The information from the regulator can also be used to calculate power usage by the battery and
the system. Measuring and storing power usage is useful to determine system power
requirements (power budget) and to help identify devices using too much power. A
CH201 12V Charging Regulator
22
Содержание CH201
Страница 1: ...06 2020 Copyright 2020 Campbell Scientific CSL I D 1352 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ...Appendix A Downloading an operating system 31 Table of Contents ii ...
Страница 42: ...FIGURE A 1 Downloading a new operating system CH201 12V Charging Regulator 32 ...
Страница 43: ......