background image

Revision:

 

09/2019

Copyright

 

©

 

2018

 

 

2019

 

Campbell

 

Scientific

Содержание CELL200 Series

Страница 1: ...Revision 09 2019 Copyright 2018 2019 Campbell Scientific ...

Страница 2: ......

Страница 3: ...s under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be given on request It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment in support of this policy a Declaration of Hazardous Material and De...

Страница 4: ......

Страница 5: ...s digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some cases alternatives are offered Details of the alternatives will be covered in separate manuals Part numbers prefixed with a symbol are special order parts for use with non EU variants or fo...

Страница 6: ......

Страница 7: ...e beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use only manufacturer recommended parts materials and tools Utility and Electrical You can be kil...

Страница 8: ......

Страница 9: ... dynamic IP 10 4 1 1 Set up hardware 10 4 1 2 Configure data logger 10 4 1 3 Set up LoggerNet 12 4 1 4 Test the connection 15 4 2 Modules using a public static IP 15 4 2 1 Set up hardware 15 4 2 2 Configure data logger 16 4 2 3 Set up LoggerNet 17 4 2 4 Test the connection 20 5 Specifications 20 6 Installation 22 6 1 Base station requirements 23 6 2 Data logger site equipment 23 6 3 Wiring and con...

Страница 10: ...onfigure data logger optional 46 6 4 4 3 Set up hardware 47 6 4 4 4 Set up LoggerNet 47 6 4 4 5 Test the connection 48 6 4 5 Serial server client mode option 49 6 4 5 1 Configure CELL200 series 50 6 4 5 2 Configure data logger 53 6 4 5 3 Set up hardware 54 6 4 5 4 Set up LoggerNet 54 6 4 5 5 Test the connection 55 7 Operation and maintenance 56 7 1 Ports 56 7 2 LED indicator lights 57 Appendix A C...

Страница 11: ...interface cell linktodevice com 80 D 2 Using Device Configuration Utility 82 Appendix E Verizon Wireless and AT T 84 E 1 Verizon Wireless 84 E 2 AT T 85 Appendix F Cellular module regulatory information 86 F 1 Important information for North American users 86 F 2 RF exposure 86 F 3 EU 87 F 4 Declaration of conformity 87 Table of Contents vi ...

Страница 12: ......

Страница 13: ... T Mobile Vodafone Telstra Other1 CELL205 4G LTE with automatic 3G fallback North America CELL210 4G LTE CAT 1 United States CELL215 4G LTE with automatic 3G and 2G fallback EMEA CELL220 4G LTE with automatic 3G fallback Australia and New Zealand CELL225 4G LTE Japan 1 More than 600 other providers are available worldwide through Campbell Scientific See Establish cellular service p 2 for more info...

Страница 14: ...ty but is less secure and more vulnerable to unsolicited traffic NOTE A public static IP account must be used when the module is set up in serial server mode Private dynamic IP accounts do not support the serial server mode 2 1 1 Campbell Scientific cellular data service Campbell Scientific can provide subscriptions to cellular service through Verizon AT T T Mobile Vodafone Telstra and over 600 ot...

Страница 15: ...ies requires a Micro SIM 3FF 6 position contacts a smartcard that securely stores the key identifying a mobile subscriber You should only need to install the SIM once in the life of the module To install the SIM card 1 Remove the SIM card cover 2 Note the location of the notched corner for correct alignment The gold contact points of the SIM face down when inserting the SIM card as shown in the fo...

Страница 16: ...a logger are supported including but not limited to PakBus email and ftp Complete the steps in the following two sections 2 3 1 Get started Open a web browser and go to www konectgds com First time users need to create a free account After you submit your information you will receive two emails up to five minutes apart One email will contain a Passport ID and the other your Password If emails are ...

Страница 17: ... came on a card with the CELL200 series 2 3 2 Set up Konect PakBus Router 1 Sign in to www konectgds com using your Passport ID and Password found in the two received emails Once logged in you will be at the Welcome page CELL200 Series 4G LTE Cellular Module 5 ...

Страница 18: ...ith your cellular enabled device and click Submit 3 The next screen shows the assigned DNS address and Port for the router An optional TCP Password may be entered for additional security and you must select a unique PakBus Address for your data logger TIP Make note of this information for use in later steps 4 Click Submit CELL200 Series 4G LTE Cellular Module 6 ...

Страница 19: ...e All settings are configured in the attached data logger l Non integrated The module mimics the behaviour of our older cellular modems Settings must be configured in both the module and the data logger l Serial Server In this mode the module receives IP communications over the cellular network and converts those to serial communications to pass on to the data logger From the perspective of the da...

Страница 20: ... each mode are shown in the following table Integrated PPP Non integrated PPP Serial server2 Serial client3 Serial server client3 CR6 series CR1000X CR300 series1 CR1000 CR3000 CR800 series CR200 X series Array based Edlog data loggers 1 Integrated PPP mode requires operating system 03 00 or later for the CR1000X 09 00 or greater for the CR6 series and 08 00 or later for the CR300 series 2 Serial ...

Страница 21: ...r information FIGURE 4 1 Static IP provisioning report Additionally Campbell Scientific cellular modules configured with a public static IP address will have two stickers on the module as shown in FIGURE 4 2 p 9 One sticker will show the module phone number and data plan The second sticker will show the static IP address Campbell Scientific cellular modules configured with a private dynamic IP add...

Страница 22: ...e Konect PakBus Router setup 3 On the Network Services tab in the PakBus TCP Client field enter the DNS address and Port number noted during the Konect PakBus Router setup 4 On the PPP tab set Config Port Used to CS I O SDC8 or RS 232 depending on how you are connected to the data logger 5 Optional On the PPP tab set User Name and Password if required by your cellular carrier usually outside of th...

Страница 23: ...to only those trusted sources Use an asterisk as a wild card For example a setting of 166 22 would allow connections from devices that have IP addresses starting with 166 22 Both IPv4 and IPv6 addresses are supported CAUTION Only set a Trusted IP address if you are familiar with their use Consult your IT department or Campbell Scientific for assistance NOTE This setting does not affect outbound co...

Страница 24: ...gured from the LoggerNet Setup screen NOTE Setup has two options EZ simplified and Standard Click on the View menu at the top of the Setup screen and select Standard view From the LoggerNet toolbar click Main Setup and configure the Network Map as described in the following steps 1 Select Add Root IPPort 2 Select PakBusPort and pbRouter for PakBus data loggers such as the CR1000X or CR300 3 Add a ...

Страница 25: ...NS address and port number are input in the Internet IP Address field separated by a colon For example axanar konectgds com pppp where pppp is the port number 5 For PakBus data loggers leave the default settings for the PakBusPort PakBus Port Always Open should not be checked If used enter the TCP Password CELL200 Series 4G LTE Cellular Module 13 ...

Страница 26: ...s data loggers select the data logger in the Network Map and set the PakBus Address to match that of the data logger default address in the data logger is 1 If a PakBus Encryption Key was entered during data logger setup also enter it here Click Apply to save the changes CELL200 Series 4G LTE Cellular Module 14 ...

Страница 27: ...e patient If the call is successful the connectors at the bottom of the screen will come together and clock information from the data logger will be displayed in the Station Date Time field If the connection fails a Communications Failure message will be displayed 4 2 Modules using a public static IP 4 2 1 Set up hardware 1 Connect the Cellular antenna 2 Connect your data logger to the CELL200 ser...

Страница 28: ...d to CS I O SDC8 or RS 232 depending on how you are connected to the data logger 3 Verify the Modem Dial String setting is blank 4 If connecting through RS 232 on the Comport Settings tab set RS232 BaudRate to 115200 Fixed 5 On the Cellular tab enter the APN provided by your cellular provider CELL200 Series 4G LTE Cellular Module 16 ...

Страница 29: ...IPv6 addresses are supported CAUTION Only set a Trusted IP address if you are familiar with their use Consult your IT department or Campbell Scientific for assistance NOTE This setting does not affect outbound connections only incoming connections In the Device Configuration Utility go to the Settings Editor then Network Services Next to the Trusted Hosts field click Edit and Add your trusted IP a...

Страница 30: ...ct Add Root IPPort 2 Select PakBusPort 3 Add a data logger to the PakBusPort 4 Select the IPPort in the Network Map Enter the CELL200 series IP address and port number The IP address and port number are input in the Internet IP Address field separated by a colon Preceding zeros are not entered in the Internet IP Address for example 070 218 074 247 is entered as 70 218 74 247 The default port numbe...

Страница 31: ... TCP Password 6 For PakBus data loggers select the data logger in the Network Map and set the PakBus Address to match that of the data logger default address in the data logger is 1 If a PakBus Encryption Key was entered during data logger setup also enter it here Click Apply to save the changes CELL200 Series 4G LTE Cellular Module 19 ...

Страница 32: ...cessful the connectors at the bottom of the screen will come together and clock information from the data logger will be displayed in the Station Date Time field If the connection fails a Communications Failure message will be displayed 5 Specifications Data Logger Compatibility The CELL200 series is compatible with the CR1000X CR300 series CR6 series CR1000 CR3000 CR800 series CR200 X series CR50...

Страница 33: ...3 900 B8 l CELL220 o Carrier Approvals Telstra o LTE 2100 B1 1800 B3 850 B5 2600 B7 700 B28 o WCDMA 2100 B1 850 B5 l CELL225 o Carrier Approvals NTT Docomo SoftBank o LTE 2100 B1 1800 B3 1880 B8 800 lower B18 00 higher B19 850 B29 Host Interfaces l CS I O communications port DB9 male l RS 232 serial port DB9 female l USB version 2 0 with micro B connector RF Connectors l 2 SMA antenna connectors p...

Страница 34: ...Max 10 Mbps download Max 5 Mbps upload l WCDMA Max 384 Kbps download Max 384 Kbps upload l GSM o EDGE Max 296 Kbps download Max 236 8 Kbps upload o GPRS Max 107 Kbps download Max 85 6 Kbps upload Compliance l View Declaration of Conformity at www campbellsci eu cell205 www campbellsci eu cell210 www campbellsci eu cell215 www campbellsci eu cell220 www campbellsci eu cell225 6 Installation 6 1 Bas...

Страница 35: ...0 CR3000 CR800 series CR5000 and GRANITE 6 9 10 l Module Interface see Module communications connections p 25 l Environmental Enclosure ENC10 12 ENC12 14 or ENC16 18 If connecting to CS I O port SC12 cable preferred for CR1000X series CR300 series CR6 series CR1000 CR3000 CR800 series CR5000 and GRANITE 6 9 10 data loggers connects the module to current data logger with a CS I O port See CS I O co...

Страница 36: ... The mounting bracket attaches to a mast or crossarm and it serves as the antenna ground plane The antenna has an N type female threaded permanent stud for easy mounting to the included bracket or through an enclosure wall A coaxial cable sold separately is required to connect this antenna to the inline surge suppression or module antenna jack The antenna includes a mount U bolt assembly for attac...

Страница 37: ...osed between the antenna and the cell tower it may attenuate the strength of the transmission signal Simply turning the enclosure 90 to 180 degrees on its mounting mast may solve weak transmission issues TIP Cellular phone apps such as OpenSignal https opensignal com show the direction to point an antenna to get the best signal strength 6 3 Wiring and connections This section explains how to conne...

Страница 38: ...e or C port to RS 232 cable or SC105 CS I O to RS 232 adapter CR200 X N A RS 232 null modem cable serial server only CR800 SC12 CS I O cable PPP and serial server RS 232 null modem cable PPP or serial server or C port to RS 232 cable or SC105 CS I O to RS 232 adapter CR1000 SC12 CS I O cable PPP and serial server RS 232 null modem cable PPP or serial server or C port to RS 232 cable or SC105 CS I ...

Страница 39: ...al server only or SC105 CS I O to RS 232 adapter CR23X PB SC12 CS I O cable serial server only SDC7 and SDC8 only RS 232 null modem cable serial server only or SC105 CS I O to RS 232 adapter FIGURE 6 1 p 27 FIGURE 6 2 p 28 and FIGURE 6 3 p 28 illustrate the most common communication connections between a data logger and a CELL200 series CS I O connection using an SC12 cable The SC12 is used to con...

Страница 40: ...ust be supplied through the Power In connector Controlling power to the CELL200 series p 58 provides an example CRBasic program using the IPNetPower instruction to control power to the CELL200 series This functionality is available in the CR300 series all operating systems the CR6 series with operating system 09 00 or greater and the CR1000X with operating system 03 00 or greater To control power ...

Страница 41: ...ut is not required Antenna diversity also called space diversity is a scheme that uses two or more antennas to improve the quality and reliability of a wireless link Often especially in urban and indoor environments there is no clear line of sight between transmitter and receiver Instead the signal is reflected along multiple paths before finally being received Each bounce can introduce phase shif...

Страница 42: ...t settings If the module is not in its default settings the settings in the CELL200 series must match those in the data logger for integrated mode to work This includes the SDC Address for CS I O communication or the RS 232 Baud Rate for RS 232 communication Once these settings match all other configuration changes can be done in the data logger as described in QuickStart integrated mode p 8 See N...

Страница 43: ... default the CELL200 series will accept incoming communications from any IP address This can be a security risk You may specify up to four IP addresses with wild cards to limit connections to only those trusted sources Use an asterisk as a wild card For example a setting of 166 22 would allow connections from devices that have IP addresses starting with 166 22 Both IPv4 and IPv6 addresses are supp...

Страница 44: ...odule has an account it can be accessed remotely using its static IP address Type the IP address into a web browser to be prompted for the user name and password 6 4 2 2 Configure data logger 1 Connect to your data logger using Device Configuration Utility 2 If using the Konect PakBus Router a On the Datalogger tab change the data logger PakBus Address and optional PakBus TCP Password to match the...

Страница 45: ...e Cellular antenna 2 Connect your data logger to the CELL200 series module RS 232 or CS I O port See Wiring and connections p 25 3 If not connecting through CS I O provide power to the CELL200 series 6 4 2 4 Set up LoggerNet The LoggerNet Network Map is configured from the LoggerNet Setup screen NOTE Setup has two options EZ simplified and Standard Click on the View menu at the top of the Setup sc...

Страница 46: ...umber are input in the Internet IP Address field separated by a colon Preceding zeros are not entered for example 070 218 074 247 is entered as 70 218 74 247 When not using Konect the default port number is 6785 5 For PakBus data loggers leave the default settings for the PakBusPort PakBus Port Always Open should not be checked If used enter the TCP Password CELL200 Series 4G LTE Cellular Module 3...

Страница 47: ...s data loggers select the data logger in the Network Map and set the PakBus Address to match that of the data logger default address in the data logger is 1 If a PakBus Encryption Key was entered during data logger setup also enter it here Click Apply to save the changes CELL200 Series 4G LTE Cellular Module 35 ...

Страница 48: ... Date Time field If the connection fails a Communications Failure message will be displayed 6 4 3 Serial server mode option In serial server mode the module receives IP communications over the cellular network and converts those to serial communications to pass on to the data logger From the perspective of the data logger this is no different than a serial cable connecting it to a computer This is...

Страница 49: ... Cellular antenna 3 Connect the Diversity antenna if used Not required See Antenna connections p 29 4 Open a web browser and go to www cell linktodevice eu TIP If your computer does not respond to the DNS server correctly browse to 192 168 86 1 5 On the Settings tab enter the APN provided by your cellular provider 6 Set Mode to Serial Server 7 Set Serial Server Listen Port Number Default is 3001 T...

Страница 50: ...Duration and Repeat Cycle For example With the following settings of Start power on Time of 22 00 On Duration of 10 minutes and Repeat Cycle of Every Hour the cellular module will turn on for ten minutes only twice each day It will turn on at 10 00 pm and 11 00 pm It will not turn on at midnight since it is powered off at the start of the next day CELL200 Series 4G LTE Cellular Module 38 ...

Страница 51: ...ld allow connections from devices that have IP addresses starting with 166 22 Both IPv4 and IPv6 addresses are supported CAUTION Only set a Trusted IP address if you are familiar with their use Consult your IT department or Campbell Scientific for assistance NOTE This setting does not affect outbound connections only incoming connections Go to the Settings then Advanced tab Enter your trusted IP a...

Страница 52: ...fixed option to match the RS 232 baud rate set in the CELL200 series module 4 If using CS I O communication the throughput can be enhanced by changing the SDC Baud Rate from 115200 to 460800 On the Advanced tab set the SDC Baud Rate to 460800 Note that if there are other devices on the CS I O port they all must be able to support this higher baud rate 6 4 3 3 Set up hardware 1 Connect the Cellular...

Страница 53: ...ber are input in the Internet IP Address field separated by a colon Preceding zeros are not entered for example 070 218 074 247 is entered as 70 218 74 247 For serial server mode the default port number is 3001 4 For PakBus data loggers leave the default settings for the PakBusPort PakBus Port Always Open it should not be checked If used enter the TCP Password CELL200 Series 4G LTE Cellular Module...

Страница 54: ...the connection After the Network Map has been configured test the cellular connection by using the Connect screen as shown in the following image Click on the appropriate station and click Connect to initiate a call to the data logger TIP The connection time is subject to many external factors It is often less than 30 seconds but could be up to fifteen minutes Be patient CELL200 Series 4G LTE Cell...

Страница 55: ...system 2 00 or newer Find the CELL200 series OS version in the OS Date field of the Status Tab For more information see Updating the operating system and firmware p 80 In serial client mode the module will connect to the cellular network and initiate a TCP client socket connection When data is sent to the active port RS 232 or CS I O it will be sent out on the TCP client connection When data is re...

Страница 56: ...described in QuickStart integrated mode p 8 6 4 4 1 Configure CELL200 series To set up the CELL200 series in serial server mode 1 Connect a USB cable between your module and computer 2 Connect the Cellular antenna 3 Connect the Diversity antenna if used Not required See Antenna connections p 29 4 Open a web browser and go to www cell linktodevice eu TIP If your computer does not respond to the DNS...

Страница 57: ...Select the Serial Mode Setup tab 8 Enter the URL and Port Number of the server device that the module will connect to 9 Optional Select Always Open for the Timeout CELL200 Series 4G LTE Cellular Module 45 ...

Страница 58: ...h day It will turn on at 10 00 pm and 11 00 pm It will not turn on at midnight since it is powered off at the start of the next day 6 4 4 2 Configure data logger optional SendVariables is used to initiate a data logger call back attempt to a computer running LoggerNet It has the following syntax SendVariables ResultCode ComPort NeighborAddr PakBusAddr Security TimeOut TableName FieldName Variable ...

Страница 59: ...lular antenna 2 Connect your data logger to the CELL200 series module RS 232 or CS I O port See Wiring and connections p 25 3 If not connecting through CS I O provide power to the CELL200 series 6 4 4 4 Set up LoggerNet The LoggerNet Network Map is configured from the LoggerNet Setup screen NOTE Setup has two options EZ simplified and Standard Click on the View menu at the top of the Setup screen ...

Страница 60: ...t the connection After the Network Map has been configured test the cellular connection by using the Connect screen as shown in the following image Click on the appropriate station and click Connect to initiate a call to the data logger TIP The connection time is subject to many external factors It is often less than 30 seconds but could be up to fifteen minutes Be patient CELL200 Series 4G LTE Ce...

Страница 61: ... Tab For more information see Updating the operating system and firmware p 80 In serial server client mode the module connects to the cellular network and opens a listening port When a client connects to the listening port the CELL200 series will be in serial server mode In serial server mode all data on the active port RS 232 or CS I O will be routed through the listening port When no client is c...

Страница 62: ...1 Configure CELL200 series To set up the CELL200 series in serial server mode 1 Connect a USB cable between your module and computer 2 Connect the Cellular antenna 3 Connect the Diversity antenna if used Not required See Antenna connections p 29 4 Open a web browser and go to www cell linktodevice eu TIP If your computer does not respond to the DNS server correctly browse to 192 168 86 1 5 On the ...

Страница 63: ...ort Number Default is 3001 This is entered along with the IP address as part of the LoggerNet configuration 9 Enter the URL and Port Number that the module will connect with 10 Optional Select Always Open for the Timeout CELL200 Series 4G LTE Cellular Module 51 ...

Страница 64: ... Duration and Repeat Cycle For example With the following settings of Start power on Time of 22 00 On Duration of 10 minutes and Repeat Cycle of Every Hour the cellular module will turn on for ten minutes only twice each day It will turn on at 10 00 pm and 11 00 pm It will not turn on at midnight since it is powered off at the start of the next day CELL200 Series 4G LTE Cellular Module 52 ...

Страница 65: ...6 22 Both IPv4 and IPv6 addresses are supported CAUTION Only set a Trusted IP address if you are familiar with their use Consult your IT department or Campbell Scientific for assistance NOTE This setting does not affect outbound connections only incoming connections Go to the Settings then Advanced tab Enter your trusted IP addresses one per line in the Trusted IP Host Addresses box 6 4 5 2 Config...

Страница 66: ...o support this higher baud rate 6 4 5 3 Set up hardware 1 Connect the Cellular antenna 2 Connect your data logger to the CELL200 series module RS 232 or CS I O port See Wiring and connections p 25 3 If not connecting through CS I O provide power to the CELL200 series 6 4 5 4 Set up LoggerNet The LoggerNet Network Map is configured from the LoggerNet Setup screen NOTE Setup has two options EZ simpl...

Страница 67: ...t the connection After the Network Map has been configured test the cellular connection by using the Connect screen as shown in the following image Click on the appropriate station and click Connect to initiate a call to the data logger TIP The connection time is subject to many external factors It is often less than 30 seconds but could be up to fifteen minutes Be patient CELL200 Series 4G LTE Ce...

Страница 68: ... loggers Its function is described throughout this manual The RS 232 port can also be used with Campbell Scientific data loggers through a null modem cable or CPI RS 232 RJ45 to DB9 cable for the CR1000X and CR6 series The USB port is used to check the module status configure the module send a new operating system or watch low level communications This is done by opening a web browser and using th...

Страница 69: ...network Flashes with traffic to from internal cell modem Flashes every 8 seconds when issue with network settings Signal Flashes every 8 seconds to indicate good signal strength Flashes every 8 seconds to indicate fair signal strength Flashes every 8 seconds to indicate marginal or no signal strength Power Traffic Flashes every 8 seconds to indicate all is good in network Flashes with traffic on R...

Страница 70: ......

Страница 71: ...stems or any CR1000 CR800 series or CR3000 you will need to use a SW12V port on the data logger and communicate over RS 232 When using a SW12V port we recommend using a PPPClose instruction to shut down the network prior to powering down the CELL200 series NOTE TimeIsBetween requires operating system version 28 00 or greater in the CR1000 CR3000 or CR800 It is supported in all CR1000X CR6 and CR30...

Страница 72: ...nd 17 00 turn the CELL200 series on for 15 minutes at the start of every hour If TimeIsBetween 9 17 24 Hr AND TimeIsBetween 0 15 60 Min Then ModuleState True Else ModuleState False EndIf Always turn OFF CELL200 series if battery drops below 11 5 volts If BattV 11 5 Then ModuleState False Set CELL200 series power to the state of ModuleState variable IPNETPower 5 ModuleState Call Data Tables and Sto...

Страница 73: ...2XX SetSettings dld CRBasic Example 2 Settings configuration and status retrieval CR300 Series Public battery_voltage Public panel_temperature_c cell modem diagnostic information Public cell_todays_usage Units cell_todays_usage KB Public cell_yesterdays_usage Units cell_yesterdays_usage KB Public cell_this_months_usage Units cell_this_months_usage KB Public cell_last_months_usage Units cell_last_m...

Страница 74: ...r Sample 1 Settings CellECIO FP2 Sample 1 cell_status String or Sample 1 Settings CellStatus String Sample 1 cell_state String or Sample 1 Settings CellState String EndTable DataTable TEST_DATA True 1 DataInterval 0 5 Min 10 Minimum 1 battery_voltage FP2 True False Sample 1 panel_temperature_c FP2 EndTable Main Program BeginProg set up attached cell2xx module via CRBasic programming SetSetting Cel...

Страница 75: ...A NextScan SlowSequence Scan 10 Min 0 0 cell_rssi Settings CellRSSI read RSSI signal strength from tower connected to cell_todays_usage Settings CellUsageToday usage reported in KB cell_yesterdays_usage Settings CellUsageYesterday usage reported in KB cell_this_months_usage Settings CellUsageMonth usage reported in KB cell_last_months_usage Settings CellUsageLastMonth usage reported in KB cell_inf...

Страница 76: ...command mode Firmware update mode Shutting down cell_rsrp Settings CellRSRP Reference signal received power for LTE in dbm Very similar to RSSI cell_ecio Settings CellECIO Reference signal received quality for 3G cell_rsrq Settings CellRSRQ Reference signal received quality for 4G cell_ip_address IPInfo 1 0 Get the TCP IP address of the PPP cellular modem interface CallTable CELL_DIAGNOSTICS NextS...

Страница 77: ...gs configuration and status retrieval p 60 illustrates how to use this functionality in a CRBasic program The functionality can also be accessed directly using the terminal emulator of the data logger in serial talk through mode The data logger terminal emulator can be accessed by connecting to the data logger in Device Configuration Utility and selecting the Terminal tab It can also be accessed f...

Страница 78: ...respond to the DNS server correctly browse to 192 168 86 1 5 On the Settings Advanced tab set the Terminal Port CS I O SDC Address It must be set to a different address than the one used for the CS I O Port SDC Address 6 Click Apply Changes CRBasic Example 3 CELL200 series settings configuration and status retrieval using terminal functionality Public modem_apn As String 50 Current Access Point Na...

Страница 79: ...ld the values returned by the modem Other variables Public battery_voltage Public panel_temperature_c DataTable CELL_DIAGNOSTICS TRUE 1 Sample 1 modem_apn String Sample 1 modem_battery_voltage FP2 Sample 1 modem_current_day_usage IEEE4 Sample 1 modem_current_month_usage IEEE4 Sample 1 modem_diversity String Sample 1 modem_ecio FP2 Sample 1 modem_ipprotocol String Sample 1 modem_mode String Sample ...

Страница 80: ...000 If returned_value APN saved Cellular module reset required _ CHR 13 Then modem_reset_needed TRUE EndIf SerialOut ComSDC11 set div 0 CRLF CRLF 1 200 Tell the modem not to use the diversity antenna on the cellular modem default 0 off 1 on SerialIn returned_value ComSDC11 100 CHR 13 1000 If returned_value Diversity saved Cellular module reset required _ CHR 13 Then modem_reset_needed TRUE EndIf S...

Страница 81: ...or billing statistics SerialIn returned_value ComSDC11 100 CHR 13 1000 SerialOut ComSDC11 set roaming auto CRLF CRLF 1 200 Set the roaming mode of the data logger Auto or disabled SerialIn returned_value ComSDC11 100 CHR 13 1000 If returned_value Roaming set to Auto Cellular module reset required _ CHR 13 Then modem_reset_needed TRUE EndIf SerialOut ComSDC11 set ipprotocol IPv4 CRLF CRLF 1 200 Set...

Страница 82: ...apn modem_battery_voltage 0 modem_current_day_usage 0 modem_current_month_usage 0 modem_diversity modem_ecio 0 modem_ipprotocol modem_mode modem_previous_day_usage 0 modem_previous_month_usage 0 modem_sdc_address 0 modem_state returned_value SerialFlush ComSDC11 clean out any garbage characters that might have come in SerialOut ComSDC11 CRLF CELL2xx 1 200 Send a CRLF and wait CELL2xx prompt before...

Страница 83: ...rsrq returned_value SerialFlush ComSDC11 SerialOut ComSDC11 show diversity CRLF CRLF 1 200 Query for the modem s current diversity antenna setting SerialIn modem_diversity ComSDC11 100 CHR 13 1000 SerialFlush ComSDC11 SerialOut ComSDC11 show ipprotocol CRLF CRLF 1 200 Query for the modem s current IP protocol configuration SerialIn modem_ipprotocol ComSDC11 100 CHR 13 1000 SerialFlush ComSDC11 Ser...

Страница 84: ...onth_usage returned_value SerialFlush ComSDC11 SerialOut ComSDC11 show usage lastmonth CRLF CRLF 1 200 Query for last month s cellular data usage SerialIn returned_value ComSDC11 100 CHR 13 1000 modem_previous_month_usage returned_value SerialFlush ComSDC11 SerialOut ComSDC11 show bat CRLF CRLF 1 200 Query for last month s cellular data usage SerialIn returned_value ComSDC11 100 CHR 13 1000 modem_...

Страница 85: ...ters that might have come in SerialOut ComSDC11 CRLF CELL2xx 1 200 Send a CRLF and wait CELL2xx prompt before continuing on SerialOut ComSDC11 wakeup CRLF CRLF 1 200 bring the modem fully back online SerialIn returned_value ComSDC11 100 CHR 13 1000 If returned_value Sleep disabled CHR 13 Then modem_is_off FALSE returned_value EndIf Loop EndIf Loop EndSequence EndProg C 2 Status commands Status com...

Страница 86: ... CS I O Port SDC Address setting in the web interface of the cellular module show listen port Displays the current setting for the cellular module TCP IP listening port used in Serial Server mode Values can range from 1 to 65535 Corresponds with the Serial Server Listen Port Number setting in the web interface of the cellular module show billing Displays the current value for the billing cycle day...

Страница 87: ...urns the model revision of the modem radio chipset show mod arev Returns the alternate or sub revision of the modem radio chipset show imei Returns the modem IMEI International Mobile Equipment Identity number show imsi Returns the modem IMSI International Mobile Subscriber Identity number show iccid Returns the modem ICCID Integrated Circuit Card Identifier number show euiccid Returns the modem E...

Страница 88: ...etwork since midnight show usage yesterday Returns the number of bytes used across the cellular network during the previous day show usage month Returns the number of bytes used across the cellular network in the current month show usage lastmonth Returns the number of bytes used across the cellular network in the previous month show reg 3g Returns information on whether or not the modem is regist...

Страница 89: ... for the user to review before installing show osupdate priority Returns the priority of the operating system update show osupdate progress Returns the progress of the CELL200 series OS update show modupdate pending Returns information regarding the module firmware Informs the user that an update is available show modupdate description Returns a description of the module firmware update for user r...

Страница 90: ...shooting show cellular log Returns a log of events for the device Useful for troubleshooting show update check Returns information concerning the last update check show diagnostic report Returns a diagnostic report that is useful for troubleshooting Combines the output of many other terminal troubleshooting commands show sms log Returns a log of SMS messaging logs C 3 Set commands Set commands are...

Страница 91: ...cepted range is 1 through 65535 set billing Sets the billing day that will be used to roll over the data usage statics in the modem is a number Accepted values are 1 to 31 set roaming Sets the roaming capabilities of the cellular modem is a string Accepted values are Auto and Disabled set ipprotocol Sets the TCP IP protocol used by the modem when communicating with the cellular network is a string...

Страница 92: ...cellular chipset only reboot Forces the modem to reboot refresh network Forces the modem to refresh its connection to the cellular network Useful for when the network goes stale long periods of inactivity check update Starts the process that checks for both a new CELL200 series OS and module firmware start modupdate Starts the module firmware update in the device This is an over the air update sta...

Страница 93: ...To prevent data loss collect all data from the data logger before proceeding to update the data logger operating system and cellular module firmware Updating the module firmware is done over the air OTA even with a direct USB connection to the data logger Therefore it can take from 5 minutes to several hours depending on signal strength between the cell tower and the CELL200 series cellular networ...

Страница 94: ...tly browse to 192 168 86 1 5 When a new CELL200 series OS is available you will see a red notification in the Version field of the Status Tab 6 Select the OS Update Tab Clicking the Apply Update button will retrieve the CELL200 series OS from the Campbell Scientific website and begin the update process If you already downloaded the OS from the Campbell Scientific website to you computer you can cl...

Страница 95: ...later for the CR1000X 09 00 or greater for the CR6 series and 08 00 or later for the CR300 series 1 Connect the Cellular antenna 2 Connect the Diversity antenna if used Not required See Antenna connections p 29 3 Connect your data logger to the CELL200 series module RS 232 or CS I O port See Wiring and connections p 25 4 If not connecting through CS I O provide power to the CELL200 series 5 Connec...

Страница 96: ... the process or Ignore to update at another time 8 Apply to save your changes 9 When new module firmware is available in the Settings Editor on the Cellular Tab you will see a field called Cellular Module OTA Update Pending This field does not appear unless an update is available Select Start Update to begin the process or Ignore to update at another time 10 Apply to save your changes CELL200 Seri...

Страница 97: ...ted IP account Also there is generally a 500 one time per customer charge to activate static IP on the account To set up an account you will need the IMEI number of the module The IMEI number is listed on a label on the module To set up an account with Verizon Wireless call 800 526 3178 for Business Sales 800 256 4646 for Personal Sales Verizon Wireless will provide a SIM Subscriber Identity Modul...

Страница 98: ...r M2M Setup Who to ask for Carlos Morales or Andy Tran An APN Access Point Name must be added onto the account to make the module accessible through the Internet For networks with fewer than 30 modules the standard I2Gold APN can be used networks with more than 30 modules will require a Custom APN A Custom APN has a setup fee starting at 500 and takes a minimum of 7 to 14 business days to complete...

Страница 99: ... to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications to this device not expressly approved by Campbell Scientific could void the user s authority to operate this equipment F 2 RF exposure In accordance with FCC IC requirements of human exposure to radio frequency fields the radiating element shall be ...

Страница 100: ...quirements and other relevant provisions of Directive 2014 53 EU RED Directive The CELL215 displays the CE mark WARNING Changes or modifications to this device not expressly approved by Campbell Scientific could void the user s authority to operate this equipment WARNING This product is only to be installed by qualified personnel F 4 Declaration of conformity The Declaration of Conformity made und...

Страница 101: ......

Страница 102: ...i cc Website www campbellsci cc France Location Vincennes France Phone 0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci de South Africa Location Stellenbosch South Africa Phone 27 21 8809960 Email sales campbellsci co za Website www campbellsci co za Southeast Asia Loc...

Отзывы: