AM16/32B Relay Multiplexer 23
B.2
Differential voltage measurement
shows a typical connection for differential voltage measurements. Using this method,
a data logger can make up to 32 differential voltage measurements through a multiplexer. See
AM16-32B Example B-3 CR300 differential measurements.CR300
,
AM16-32B Example B-4 CR1000X
differential measurements.CR1X
, and
for the programs and wiring diagram, or use
Short
Cut to create the program. With minor adjustments, the CR1000X program can be used with the
CR6, CR3000, CR800 series, or CR1000. In either case, the AM16/32B must be in 2x32 mode. View
the program in the
CRBasic Editor.
FIGURE B-2. Typical differential voltage measurement connection
These programs use arrays for multipliers and offsets. This allows individual adjustment of the
multiplier and offset for each sensor. For example, in this program the third multiplier,
8, and the
third offset,
9, would be applied to the third measurement,
DiffV(3)
.
Table B-2. Wiring for differential voltage measurements CRBasic example
CR1000X
CR300
AM16/32B in 2X32 mode
Sensors
Control and
COM terminals
Measurement
terminals
1H
1H
COM ODD H
H
High signal
1L
1L
COM ODD L
L
Low signal
⏚
(Signal Ground)
⏚
(Signal Ground)
COM
Shield
12V
SW12V
12V
G
G
G
C1
C1
CLK
C2
C2
RES