background image

AM-ENCT ANALOG MULTIPLEXER ENCLOSURE

2

2.  SPECIFICATIONS

Dimensions:

External:  11.3" W x 13.5" L x 5.56" D
Internal:  10" W x 12" L x 5.25" D

Weight

:  approx.  12.6 lbs.

with AM416 installed:  approx.  14.2 lbs.
with AM32 installed:  approx.  14.0 lbs.
shipping:  approx.  18.0 lbs.

NEMA Rating

:  Prior to modification--

3,3R,3S,4,4X,6,6P,12,13.

Lid attachment

:  Hinged; sealed with poured-

in-place internal gasket.  Un-hinged side
secured with two captive screws.

Conduit diameter

:

with reducing plug:  0.5"
without reducing plug:  1.25"

3.  INSTALLATION

If the multiplexer was not installed at the factory,
the enclosure will contain a small plastic bag
with the following parts:

(4)  3/8" screws
(4)  #6 washers
(4)  3/8" spacers

3.1  AM416

The AM416 requires two 3/8" screws to attach it
to the mounting plate.  The additional enclosed
hardware is not required for AM416 installation.

Tools required: #1 Phillips screwdriver, flat-
bladed screwdriver

1.  Remove the four phillips screws at the

corners of the AM416 and remove the cover
plate.  Care must be taken when removing
the upper plate of the multiplexer.  It is
generally easiest to lift the edge opposite
the strain relief flange up first, then slide the
plate out.  Make sure to clear the terminal
strips.

2.  Remove the two screws at the center of the

printed circuit board and then remove the
printed circuit board.  Place the board on a
clean, dry surface.

3.  Remove and dispose the four rubber feet

from the back panel of the AM416.

4.  Open the AM-ENCT enclosure and remove

the cover plate and foam insulation (Figure
1). The multiplexer mounts to the backplate
labeled "1A" in Figure 1.

5.  Align the two holes through the back panel

of the multiplexer with the holes on the
mounting plate.  Attach the back plate of the
AM416 to the mounting plate with two 3/8"
screws from the plastic bag.

6.  Reassemble the multiplexer.

7.  Re-insert the insulating foam and attach the

AM-ENCT cover plate.

3.2  AM32

The AM32 requires four 3/8" screws, four
spacers, and four washers to attach it to the
internal mounting plate.

Tools required:  flat-bladed screwdriver

1.  Assembly of the AM32 and AM-ENCT is the

same as the AM416 except that
disassembly of the multiplexer is not
required.

2.  Install the four 3/8" spacers in the enclosure

base mounting plate.

3.  Attach the AM32 to the base mounting plate

with the four 3/8" screws and washers.

4.  Re-insert the insulating foam and attach the

AM-ENCT cover plate.

3.3  MOUNTING ENCLOSURE

Two 1.25" x 5/16" U-bolts (provided) attach the
enclosure to a 1.25" schedule 40 pipe.  The U-
bolts and brackets can be removed to mount
the enclosure against a flat surface.  Four user-
supplied 5/16" diameter screws or bolts can be
used for this purpose.  The type and length of
the screws or bolts depends on the composition
of the supporting surface.  To prevent damage
to the fiberglass enclosure, use the washers
from the U-bolt bracket and do not over-tighten
the mounting screws (bolts).

Содержание AM-ENCT

Страница 1: ...INSTRUCTION MANUAL AM ENCT Analog Multiplexer Enclosure Revision 12 91 C o p y r i g h t c 1 9 8 9 1 9 9 1 C a m p b e l l S c i e n t i f i c I n c ...

Страница 2: ... all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc d...

Страница 3: ... is ordered with an AM416 or AM32 multiplexer the multiplexer is mounted in the AM ENCT at the factory If the AM ENCT and multiplexer are ordered separately some user assembly is required The AM ENCT protects the multiplexer from windblown dust rain and sleet The AM ENCT s insulation and internal aluminum plates reduce temperature gradients across the multiplexer terminal strips Smaller thermal gr...

Страница 4: ... dry surface 3 Remove and dispose the four rubber feet from the back panel of the AM416 4 Open the AM ENCT enclosure and remove the cover plate and foam insulation Figure 1 The multiplexer mounts to the backplate labeled 1A in Figure 1 5 Align the two holes through the back panel of the multiplexer with the holes on the mounting plate Attach the back plate of the AM416 to the mounting plate with t...

Страница 5: ... recommended Desiccant should be used inside the AM ENCT to help reduce water vapor Desiccant should be replaced regularly Desiccant life is prolonged by plugging the cable entry port with electrician s putty or foam NOTE Because lead acid batteries may emit explosive hydrogen gas DO NOT seal an enclosure containing lead acid batteries Aluminum Plate A Figure 1 provides a framework for thermocoupl...

Страница 6: ...AM ENCT ANALOG MULTIPLEXER ENCLOSURE 4 FIGURE 2 Thermocouple Lead Wire Routing ...

Страница 7: ...This is a blank page ...

Страница 8: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Отзывы: