background image

11-24VDC @ 25W, power
input screw terminals:

40 W maximum, reverse polarity protected

On/Off power switch

Special features:

HANDSET socket:

Supports FAA handset with electret microphone including bias
and speaker

RJ11

VOICE MODEM socket:

Telephone dial in voice modem

RJ11

NOTE:
Hand held microphone with PTT and audio Out CH1 cannot be used as they are used to
support the FAA handset function.

4.2 Front panel

MIC PTT:

Supports Electret hand-held microphone with PTT button

3.5 mm jack, 3-pole

Switch closure compatible PTT input

Loudspeaker:

Monitors selected audio source (user-adjustable audio volume)

Line in right channel (internal)

Line out left channel (internal).

Line out right channel (internal).

VOL/DATA dial:

Volume control

Navigate menus and data entry

AeroX Audio105

4

Содержание AeroX Audio 105

Страница 1: ...03 2023 Copyright 2023 Campbell Scientific Inc...

Страница 2: ...ess 10 6 3 VOL DATA dial 10 6 4 PTT microphone 11 6 5 Audio outputs 11 6 6 Audio inputs 12 6 7 PTT connector 13 6 8 LIGHTS connector 15 6 9 VOICE MODEM connector 15 6 10 HANDSET connector 15 6 11 USB...

Страница 3: ...nsmitted are the weather conditions at the airport as well as operational information such as the current runway in use available approaches the state of the runway and breaking conditions Other infor...

Страница 4: ...DC 25 W typical 40 W maximum Temperature 20 to 70 C NOTE The display limits operational temperature range to 20 to 70 C but a heater fitted on the display back can increase that range Contact factory...

Страница 5: ...wns 25 way D plug Isolated auxiliary digital input 3 5 to 12 V LIGHTS terminal strip Four screw terminals Volt free break before make normally open closed relay contacts contact rating 50 V 1 A NOT pr...

Страница 6: ...icrophone with PTT and audio Out CH1 cannot be used as they are used to support the FAA handset function 4 2 Front panel MIC PTT Supports Electret hand held microphone with PTT button 3 5 mm jack 3 po...

Страница 7: ...dy state when power on and status ok Flashing when power on but error detected When this occurs all VU LEDs will be continuously lit until the error is cleared LCD color display Show status Data entry...

Страница 8: ...nd Table 5 2 AUDIO OUT 3 5 mm 3 pole jack Component Description Schematic Sleeve audio Ring audio Tip audio Table 5 3 AUDIO IN XLR female 3 pin terminal Pin Description Schematic 1 ground 2 audio 3 au...

Страница 9: ...losed contact 18 PTT3 common 6 PTT3 normally open contact 19 ground 7 PTT4 normally closed contact 20 PTT4 common 8 PTT4 normally open contact 21 ground 9 PTT5 normally closed contact 22 PTT5 common 1...

Страница 10: ...round shell ground Table 5 8 Chassis main power inlet IEC C14 Pin Description Schematic L live phase N neutral phase E protective earth Table 5 9 11 24VDC screw terminal strip Terminal Description Sch...

Страница 11: ...Pin RJ12 Description Schematic 1 2 Black microphone 2 3 Red speaker 3 4 Green speaker 4 5 Yellow microphone Table 5 12 VOICE modem socket 4 Pin RJ11 6 4 Pin RJ12 Description Schematic 1 2 2 3 Ring li...

Страница 12: ...me operational after power up or reset Initially the POWER and VU LEDs illuminate After 5 seconds the AeroX Audio105 beeps and the LCD displays the Campbell Scientific logo A solid POWER LED not flash...

Страница 13: ...ation 6 5 Audio outputs The five male 3 pin XLR connectors and 3 5 mm jacks CH1 to CH5 on the rear panel are isolated transformer coupled with a 600 ohm impedance and pro audio levels The volume level...

Страница 14: ...onnector with a latch It is transformer isolated and the sensitivity can be adjusted during configuration A 3 5 mm Jack is wired in parallel to the XLR connector for connecting standard stereo headpho...

Страница 15: ...VAC or DC at 1 A but are NOT overload protected Maximum voltage on any contact relative to ground is 50 VAC or DC The contacts are configured as break before make change over contacts with the normal...

Страница 16: ...can be used with special software contact factory for support Maximum common mode voltage for pins 11 and 24 relative to ground is 15 V Input pins 11 and 24 are reverse polarity protected and is activ...

Страница 17: ...rts voice and DTFM decoding as required by NOAA contact factory The voice modem is connected to COM4 of the single board computer internally 6 10 HANDSET connector This RJ11 connector provides line ou...

Страница 18: ...ronics controls the audio routing and level provides regulated power supplies and a Watch dog timer function and internally connects to COM2 of the single board computer 7 Troubleshooting 7 1 AudioSer...

Страница 19: ...n Updating the firmware is similar to updating the AeroX Audio105 software Loading new edited firmware to the micro controller 1 Place the file on a USB flash drive in the AudioServer directory Name t...

Страница 20: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more informat...

Страница 21: ...ion or Repair Reference number contact your CAMPBELL SCIENTIFIC regional office Please write the issued number clearly on the outside of the shipping container and ship as directed For all returns the...

Страница 22: ...rohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers l Use only manufacturer recommended parts materials and tools Utility and Electrical l Y...

Страница 23: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: