4GMini/4GPlus Cellular Modem
A-7
4. RF401A Spread Spectrum Radio – base (at NL201)
i.
Set the configuration to
TCP serial
.
ii.
If the use of a port other than 6784 is required, change the service port.
FIGURE A-10. Device Configuration Utility – RF401A Series
5. RF401A Spread Spectrum Radio – remote (at CR1000)
i.
Set the active interface to
RS-232
.
ii.
Set the protocol to
Transparent.
iii.
Apply
the configuration.
6. LoggerNet Setup for CR1000 Remote Communication
i.
Add an IP port – enter the static IP or Dynamic DNS details for the
4GMini/4GPlus Cellular Modem, followed by 6784.
ii.
Add a PakBus port and a CR1000 series. In this example, the two
elements of LoggerNet setup stay in their default state.