![Campbell 03002 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/campbell/03002/03002_instruction-manual_489153025.webp)
R.M. Young Wind Sentry
16
2. Disconnect the sensor from the datalogger and use an ohm meter to check
the coil. The resistance between the white and black wires for the 03101
and black and red wires for the 03002 should be a nominal 1300 ohms.
Infinite resistance indicates an open coil; low resistance indicates a
shorted coil.
3. Verify that the configuration code, and multiplier and offset parameters
for the pulse count instruction are correct for the datalogger type.
10. References
Component part numbers and other information is available in the R.M. Young
www.campbellsci.com/03002-wind-sentry
. Because
Campbell Scientific cables the sensor, the wiring in the R.M. Young manual
will be different than the wiring listed in this manual.
The following references give detailed information on siting wind speed and
wind direction sensors.
EPA, 1989:
Quality Assurance Handbook for Air Pollution Measurements
System
, Office of Research and Development, Research Triangle Park,
NC, 27711.
EPA, 1987:
On-Site Meteorological Program Guidance for Regulatory
Modeling Applications,
EPA-450/4-87-013, Office of Air Quality Planning
and Standards, Research Triangle Park, NC 27711.
The State Climatologist, 1985:
Publication of the American Association of
State Climatologists: Height and Exposure Standards
, for Sensors on
Automated Weather Stations, vol. 9, No. 4.
WMO, 1983:
Guide to Meteorological Instruments and Methods of
Observation,
World Meteorological Organization, No. 8, 5th edition,
Geneva, Switzerland.