1. Introduction
The 03002 Wind Sentry Set measures both wind speed and direction. It consists of a 3-cup
anemometer and a wind vane mounted on a small crossarm. The anemometer and vane may be
purchased separately.
NOTE:
This manual provides information only for CRBasic data loggers. For retired Edlog data logger
support, see an older manual at
www.campbellsci.com/old-manuals
.
2. Precautions
l
READ AND UNDERSTAND the
section at the back of this manual.
l
The 03002 is a precision instrument. Please handle it with care.
l
Do not use cable lengths greater than 30 m (9 ft) in electrically noisy environments.
l
The black outer jacket of the cable is Santoprene® rubber. This compound was chosen for
its resistance to temperature extremes, moisture, and ultraviolet (UV) degradation.
However, this jacket will support combustion in air. It is rated as slow burning when tested
according to U.L. 94 H.B. and will pass FMVSS302. Local fire codes may preclude its use
inside buildings.
l
Wire color and functions of sensors purchased through Campbell Scientific may not
correspond with the wire colors and functions given in the manufacturer’s manual. To
ensure proper function, follow the wiring provided in
Short Cut
or in the Campbell Scientific
manual.
3. Initial inspection
l
Upon receipt of the 03002, inspect the packaging and contents for damage. File damage
claims with the shipping company. Immediately check package contents against the
shipping documentation. Contact Campbell Scientific about any discrepancies.