3

TF2101, TF2111, TQ3010, TQ3011, TX2101, TX2118

Installation 

(Continued)

 

Do not locate the  

  compressor air  

inlet near steam, paint spray, 
sandblast areas or any other source 
of contamination.

NOTE: 

If compressor operates in a hot, 

moist environment, supply compressor 
pump with clean, dry outside air. Supply 
air should be piped in from external 
sources. For two-stage compressors 
only, use adapter kit (TF060502AV) 
to connect piping to compressor. Two 
adapter kits are needed for two-stage 
10 and 15 HP units.

TANK MOUNTING

The tank should be bolted into a flat, 
even, concrete floor or on a separate 
concrete foundation. Vibration isolators 
should be used between the tank leg 
and the floor. Model MP367700AJ 
isolator pads are recommended for 
horizontal units. Model MP345700AJ 
isolator pads are recommended for 
vertical units. When using isolator 
pads, 

do not draw bolts tight

. Allow 

the pads to absorb vibrations. When 
isolators are used, a flexible hose or 
coupling should be installed between 
the tank and service piping.

 

  Failure 

to properly install the 
tank can lead to cracks 
at the welded joints and 
possible bursting.

PIPING

 

Never use plastic  

  (PVC) pipe for 

compressed air. Serious injury or 
death could result.

Any tube, pipe or hose connected to 
the unit must be able to withstand the 
temperature generated and retain the 
pressure. All pressurized components 
of the air system must have a pressure 
rating higher than or equal to the  
200 psi for two-stage compressors or 
150 psi for single stage compressors 
ASME safety valve setting.  

Incorrect selection and installation of 
any tube, pipe or hose could result in 
bursting and injury. Connect piping 
system to tank using the same size 
fitting as the discharge port.

INSTALLING A SHUT-OFF VALVE

A shut-off valve should be installed 
on the discharge port of the tank to 
control the air flow out of the tank. 
The valve should be located between 
the tank and the piping system. 

 

Never install a  

  shut-off valve 

between the compressor pump 
and the tank. Personal injury and/
or equipment damage may occur. 
Never use reducers in discharge 
piping.

When creating a permanently installed 
system to distribute compressed air, 
find the total length of the system and 
select pipe size from the chart. Bury 
underground lines below the frost line 
and avoid pockets where condensation 
can gather and freeze.

Apply air pressure to the piping 
installation and make sure all joints are 
free from leaks BEFORE underground 
lines are covered. Before putting the 
compressor into service, find and repair 
all leaks in the piping, fittings and 
connections.

Chart 1:

 Minimum Pipe Size for  

Compressed Air Line (in inches)

Length Of Piping  

System (in feet)

CFM

25

50

100

250

10

1/2

1/2

3/4

3/4

20

3/4

3/4

3/4

1

40

3/4

1

1

1

60

3/4

1

1

1

100

1

1

1

1-1/4

Drain Valve

Isolation Pad 

(available separately)

Tank

Discharge 
Port

Tank Shut-Off Valve 
(available separately)

Discharge 
Port

Tank Shut-Off Valve 
(available separately)

Pressure 

Gauge

Pressure 

Gauge

Factory Mounted 

Magnetic Starter 

(not on all units)

Pressure 
Switch

Pressure 
Switch

Safety 
Valve

Motor

Motor

Pump

Pump

Check 

Valve

Discharge 

Tube

Discharge 

Tube

Safety Valve 

Access

Figure 1 - Vertical Unit Identification

All manuals and user guides at all-guides.com

Содержание TF2111

Страница 1: ...product Operating Instructions TF2101 TF2111 TQ3010 TQ3011 TX2101 TX2118 REMINDER Keep your dated proof of purchase for warranty purposes Attach it to this manual or file it for safekeeping Unpacking...

Страница 2: ...ts from bursting The flow rating can be found in the parts manual The maximum safe pressure rating for the pump is 200 psi two stage or 150 psi single stage The safety valve in the intercooler does no...

Страница 3: ...y valve setting Incorrect selection and installation of any tube pipe or hose could result in bursting and injury Connect piping system to tank using the same size fitting as the discharge port INSTAL...

Страница 4: ...the applicable article For Motors and Motor Controllers Article 430 Table 430 1 52 IMPORTANT Overload protection is required for all motors Certain motors have this protection built in To determine if...

Страница 5: ...Mobil 1 5W30 or 10W30 synthetic oil may also be used Add oil only through the oil fill plug Pouring oil into any other orifice will cause oil to leak and spray out during operation TF2101 TF2111 TQ301...

Страница 6: ...Disconnect tag and lock out power source then release all pressure from the system before attempting to install service relocate or perform any maintenance In order to maintain efficient operation of...

Страница 7: ...lts Slots in the bed plate allow for sliding the motor back and forth to adjust belt tension STORAGE If compressor is to be stored for a short period of time make sure that it is stored in a normal po...

Страница 8: ...3 Check tank for cracks or pin holes 3 Replace tank Never repair a damaged tank Excessive belt wear Light dust from start is normal Worn belts separate at layers 1 Pulley out of alignment 1 Realign m...

Страница 9: ...TF2101 TF2111 TQ3010 TQ3011 TX2101 TX2118 9 Service Record Date Maintenance Performed Replacement Components Required All manuals and user guides at all guides com...

Страница 10: ...ntact with tools or surroundings b Pump or valve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functio...