3
VT6315, VT6358, VT6361
www.chpower.com
Operating Instructions
Introduction
Refer to Figure 1 to locate the following
items .
Pressure switch -
Auto/Off Switch - In
the AUTO position, the compressor
shuts off automatically when tank
pressure reaches the maximum preset
pressure . After air is used from the tank
and drops to a preset low level, the
pressure switch automatically turns the
motor back on . In the OFF position, the
compressor will not operate . This switch
should be in the OFF position when
connecting or disconnecting the power
cord from the electrical outlet .
When the pressure switch turns the
motor off you will hear air leaking out
of the pressure switch unloader valve
for a short time . This releases the air
pressure from the discharge tube and
allows the compressor to restart easier .
Regulator -
The regulator controls the
amount of air pressure released at the
hose outlet .
Assembly
HANDLE ASSEMBLY - Handle may be
pre-assembled on some units .
Insert four handle screws through holes
in handle and tighten to tank baseplate
(See Figure 2) .
FOOT ASSEMBLY
The items marked with an asterisk (*)
were shipped loose with the unit (See
Figure 3) .
1 . Tilt unit to allow access to front foot
and secure properly to ensure unit
does not tip over .
2 . Insert bolt through foot and bracket .
The foot should be on the lower side
of bracket .
3 . Tightly secure with the lock nut .
Repeat on opposite side .
ASMe Safety Valve -
This valve
automatically releases air if the tank
pressure exceeds the preset maximum .
Discharge tube -
This tube carries
compressed air from the pump to the
check valve . This tube becomes very hot
during use . To avoid the risk of severe
burns, never touch the discharge tube .
To avoid the risk of
severe burns, never
touch the discharge tube.
Check valve -
One-way valve that
allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump .
handle -
Designed to move the
compressor .
Never use the
handle to lift the
unit completely off the ground. Handle
is intended only for pushing or pulling
product.
Belt Guard -
Covers the belt, motor
pulley and flywheel .
Never
operate
compressor without a
beltguard. This unit can
start automatically without
warning. Personal injury or property
damage could occur from contact with
moving parts.
Tank Drain Valve -
This valve is located
on the bottom of the tank . Use this
valve to drain moisture from the tank
daily to reduce the risk of corrosion .
Reduce tank pressure below 10 psi,
before opening drain valve .
Tank Pressure Gauge -
Indicates
amount of air pressure stored in tank .
hose Pressure Gauge -
Indicates
amount of air pressure in hose used to
operate tools . This pressure is increased
or decreased by the regulator .
Drain
Petcock
Handle
Discharge Tube
Check Valve
Belt Guard
Tank
Breather/
Dipstick
& Oil Fill
Hole
Intake Filter
Hose
Pressure
Gauge
Pressure
Switch
Figure 1
Figure 2
Tank Baseplate
Handle Screw
Handle
Figure 3
Foot*
Wheel*
Lock Nut*
Shoulder Bolt*
Nut*
Bolt*