manualshive.com logo in svg
background image

Operating Instructions and Parts List

2

www.chpower.com

FP202800, FP202900

General Safety Information

CALIFORNIA PROPOSITION 65

 

This product or its

  power cord may 

contain chemicals, including lead, 
known to the State of California to 
cause cancer and birth defects or other 
reproductive harm. Wash hands after 
handling.

  You 

can 

 create 

dust when you cut, sand, 
drill or grind materials 
such as wood, paint, metal, 
concrete, cement, or other masonry. 
This dust often contains chemicals 
known to cause cancer, birth defects, 
or other reproductive harm. Wear 
protective gear.

GENERAL SAFETY

 Since the air compressor and other 
components (material pump, spray 
guns, filters, lubricators, hoses, 
etc.) used, make up a high pressure 
pumping system, the following safety 
precautions must be observed at all 
times:

 1.  Read all manuals 

included with this 
product carefully. Be 
thoroughly familiar with 
the controls and the proper use of 
the equipment.

 2.  Follow all local electrical and safety 

codes as well as in the United 
States, the National Electrical Codes 
(NEC) and Occupational Safety and 
Health Act (OSHA).

 3.  Only persons well acquainted 

with these rules of safe operation 
should be allowed to use the 
compressor.

4.  Keep visitors away and NEVER 

allow children in the work area.

5.  Wear safety glasses and 

use hearing protection 
when operating the 
unit.

6.  Do not stand on or use the unit as 

a handhold.

7.  Before each use, inspect 

compressed air system and 
electrical components for signs of 
damage,  deterioration, weakness 
or leakage. Repair or replace 
defective items before using.

8.  Check all fasteners at frequent 

intervals for proper tightness.

 Motors, 

   electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a fl ammable gas 
or vapor. Never operate or repair in or 
near a fl ammable gas or vapor. Never 
store fl ammable liquids or gases in the 
vicinity of the compressor.

 

 

Compressor parts may 
be hot even if the unit is 
stopped.

 9.  Keep fingers away from a 

running compressor; fast moving 
and hot parts will cause injury and/
or burns.

10. If the equipment should start 

to vibrate abnormally, STOP 
the engine/motor and check 
immediately for the cause. 
Vibration is generally a warning of 
trouble.

11. To reduce fire hazard, keep engine/

motor exterior free of oil, solvent, 
or excessive grease.

 

  An ASME code

  safety relief valve 

with a setting no higher than 150 psi 
MUST be installed in the tank for this 
compressor. The ASME safety valve 
must have suffi cient fl ow and pressure 
ratings to protect the pressurized 
components from bursting.

 See 

compressor 

   specifi cation decal 

for maximum operating pressure. 
Do not operate with pressure switch 
or pilot valves set higher than the 
maximum operating pressure.

12. Never attempt to adjust ASME 

safety valve. Keep safety valve 
free from paint and other 
accumulations.

 

Never use plastic

  (PVC) pipe for 

compressed air. Serious injury or death 
could result.

 Never 

   attempt 

to repair or modify a tank! 
Welding, drilling or any 
other modifi cation will 
weaken the tank resulting in damage 
from rupture or explosion. Always 
replace worn, cracked or damaged 
tanks.

 

 Drain liquid from 

 tank 

daily.

 13. Tanks rust from moisture build-up, 

which weakens the tank. Make 
sure to drain tank regularly and 
inspect periodically for unsafe 
conditions such as rust formation 
and corrosion.

14. Fast moving air will stir up dust 

and debris which may be harmful. 
Release air slowly when draining 
moisture or depressurizing the 
compressor system.

SPRAYING PRECAUTIONS

 Do 

not 

    spray 

fl ammable materials in 
vicinity of open fl ame 
or near ignition sources 
including the compressor unit.

 15. Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

16. Use a face mask / 

respirator when spraying 
and spray in a well 
ventilated area to 
prevent health and fire 
hazards.

17. Do not direct paint or other 

sprayed material at the compressor. 
Locate compressor as far away 
from the spraying area as 
possible to minimize overspray 
accumulation on the compressor.

18. When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

 Introduction

 R efer to Figure 4 to locate the 
following items.

ON / OFF Switch ( I / O ) - 

Push 

switch to the ON ( 

I

 ) position to turn 

compressor on. Push switch to the OFF 

O

 ) position to turn compressor off. 

This switch should be in the OFF ( 

O

 ) 

position when connecting / 
disconnecting power cord from 
electrical outlet or when changing 
tools.

MANUAL

Figure 1

Содержание FP202800

Страница 1: ...nt information that if not followed may cause damage to equipment NOTE Information that requires special attention Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an imminently hazardous situatio...

Страница 2: ...k immediately for the cause Vibration is generally a warning of trouble 11 To reduce fire hazard keep engine motor exterior free of oil solvent or excessive grease An ASME code safety relief valve with a setting no higher than 150 psi MUST be installed in the tank for this compressor The ASME safety valve must have sufficient flow and pressure ratings to protect the pressurized components from bur...

Страница 3: ...g plug that looks like the plug illustrated in Figure 3 Make sure the product is connected to an outlet having the same configuration as the plug This product must be grounded In the event of an electrical short circuit grounding reduces risk of electrical shock by providing an escape wire for electric current This product is equipped with a cord having a grounding wire with an appropriate groundi...

Страница 4: ...urn ON OFF switch to ON position and let compressor run until it reaches automatic shutoff pressure 6 Attach tire chuck or tool to end of hose 7 Turn regulator knob clockwise to the right to desired pressure of tool being used Operation START UP Do not attach air tools to open end of the hose until start up is completed and the unit checks OK ON OFF CYCLING OF COMPRESSOR In the ON AUTO position th...

Страница 5: ...released when you pull on the ring or if it does not close automatically it MUST be replaced DRAIN TANK With compressor shut off and pressure released drain moisture from tank by opening drain valve underneath tank CLEANING Turn power OFF and clean dust and dirt from pump cover tank and air lines IMPORTANT Unit should be located as far from spraying area as hose will allow to prevent over spray fr...

Страница 6: ...se drain valve 1 Tighten 2 Check valve leaking 2 Remove check valve Clean or replace 3 Loose connections at fittings tubing etc 3 Check all connections with soap and water solution If a leak is detected 1 tighten or 2 remove fitting and apply pipe tape to threads and reassemble 4 Tank leaks 4 Check tank for leaks with soap and water solution If leak is detected tank must be replaced with genuine r...

Страница 7: ...09530AV 1 10 Check valve includes part 29 30 FP209532AV 1 11 M4 x 0 7 x 6 screw 1 12 M6 x 1 0 x 10 screw 4 13 Drain valve D 1403 1 14 Rubber foot tank 3 15 Wire pressure switch to power switch FP209523AV 1 16 Power cord 1 17 M3 x 10 screw 1 18 Pump motor assembly includes part 21 FP209039AV 1 19 Motor cover 1 20 Wire clip FP202823AV 1 Ref Part No Description Number Qty 21 Exhaust tube kit FP202839...

Страница 8: ...mp or valve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due to improper drainage or corrosive environments e The following components are considered normal wear items and are not covered after the first year of ownership Electric motor c...

Страница 9: ...RVER CES INSTRUCTIONS NE PAS JETER Directives de Sécurité Ce manuel contient de l information très importante qui est fournie pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D ÉQUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dangereuse imminente qui MÈNERA à la mort ou à des blessures graves si elle n est pas évitée Avertissement indique une situation p...

Страница 10: ...ion est généralement une indication d un problème 11 Pour réduire le risque d incendie garder l extérieur du moteur libre d huile de solvants et de graisse excessive Une soupape de sûreté ASME avec une classification qui ne dépasse pas 1034 kPa doit être installée dans le réservoir de ce compresseur La soupape de sûreté ASME doit avoir un débit d air et une classification de pression suffisants po...

Страница 11: ... le fil de terre à ni une ni l autre borne plate Le fil avec l isolation qui a une surface externe verte avec ou sans rayures est le fil de terre Ne jamais brancher le fil vert ou vert et jaune à une borne électrisée Installation ENDROIT Il est extrêmement important d installer le compresseur dans un endroit propre sec et bien ventilé Le compresseur doit être placé sur une surface solide et à nive...

Страница 12: ...tuyau 7 Tourner le bouton du régulateur complètement vers la droite dans le sens des aiguilles d une montre jusqu à la pression voulue pour l outil utilisé Fonctionnement DÉMARRAGE Ne pas attacher des outils pneumatiques au bout ouvert du tuyau avant que le démarrage du modèle soit complet et que vous avez vérifié le modèle CYCLE MARCHE ARRÊT DU COMPRESSEUR En position ON AUTO marche auto le compr...

Страница 13: ...sortir l air en tirant sur l anneau ou si elle ne se ferme pas automatiquement il FAUT la remplacer PURGER LE RÉSERVOIR Avec le compresseur hors circuit et la pression dissipée purger l humidité du réservoir en ouvrant le robinet de purge sous le réservoir NETTOYAGE Mettre hors circuit OFF et nettoyer la poussière et la saleté du couvercle de la pompe du réservoir et des canalisations d air IMPORT...

Страница 14: ...ou remplacer 3 Connexions desserrées aux raccords tubes etc 3 Vérifier toutes les connexions avec une solution de savon et d eau S il y a une fuite 1 resserrer ou 2 retirer le raccord et appliquer du ruban à tuyau pour les filets et remonter 4 Fuite du réservoir 4 Vérifier le réservoir pour les fuites avec une solution de savon et d eau S il y a une fuite le réservoir doit être remplacé avec une p...

Страница 15: ...nclut pièces nº 29 et 30 FP209532AV 1 11 Vis M4 x 0 7 x 6 1 12 Vis M6 x 1 0 x 10 4 13 Robinet de purge D 1403 1 14 Pied en caoutchouc Réservoir 3 15 Fil pressostat avec interrupteur FP209523AV 1 16 Cordon d alimentation 1 17 Vis M3 x 10 1 18 Montage de pompe moteur Inclut pièce nº 21 FP209039AV 1 19 Couvercle de moteur 1 20 Attache de fils FP202823AV 1 21 Kit de tuyau de ventilation FP202839AV 1 2...

Страница 16: ...orme qui n ont pas d effet sur le fonctionnement du compresseur d Les réservoirs rouillés y compris mais sans s y limiter à la rouille causée par la vidange incorrecte ou par un environnement corrosif e Les composants suivants sont considérés comme des articles sujets à l usure normale et ne sont pas couverts après le premier an de possession Moteur électrique soupape de retenue interrupteur de pr...

Страница 17: ...ODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene información que es muy importante que sepa y comprenda Esta información se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes símbolos Peligro indica una situación inminentemente peligrosa que si no se evita dará como resultado la mue...

Страница 18: ...ntenga los dedos alejados del compresor cuando esté funcionando las piezas en movimiento o calientes le ocasionarían heridas y o quemaduras 10 Si el equipo comienza a vibrar excesivamente APAGUE la unidad y chequéela inmediatamente para determinar el problema Generalmente la vibración se debe a una falla 11 Para reducir el peligro de incendios mantenga el exterior del compresor limpio sin aceite s...

Страница 19: ... un espacio mínimo de 45 7 cm 18 pulgadas entre el compresor y la pared ya que los objectos podrían obstruir el paso de aire No coloque la entrada de aire del compresor cerca de áreas con vapor vapores de pintura chorros de arena o cualquier otra fuente de contaminación Los desperdicios dañarán el motor Manómetros Hay dos tipos de manómetros ubicados cerca del regulador Estos manómetros indican la...

Страница 20: ...F apagado 4 Enchufe el cable de corriente 5 Coloque el interruptor de encendido apagado en la posición ON encendido Deje que el compresor funcione durante 30 minutos 6 Coloque el interruptor de encendido apagado en la posición OFF apagado 7 Desenchufe el cable de corriente Ahora el compresor está listo para ser usado ANTES DE INICIAR CADA PROCEDIMIENTO DE ENCENDIDO 1 Gire la perilla del regulador ...

Страница 21: ...s de aire IMPORTANTE El compresor debe colocarse lo más lejos posible del área de pulverización según lo permita la HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida que sale de la bomba Cuando el nivel de humedad es muy alto o cuando el compresor ha estado en uso continuo por mucho tiempo esta humedad se acumulará en el tanque Cuando esté...

Страница 22: ...drenaje floja 1 Ajuste 2 Fugas en la válvula de retención 2 Retire la válvula de retención Limpie o reemplace 3 Conexiones flojas en los accesorios tubería etc 3 Revise todas las conexiones con una solución de agua y jabón Si detecta una fuga 1 ajuste o 2 retire las conexiones y aplique cinta para tuberías en las roscas y vuelva a ensamblar 4 Fugas del tanque 4 Revise el tanque en busca de fugas c...

Страница 23: ...chequeo incluye piezas No 29 y 30 FP209532AV 1 11 Tornillo M4x0 7x6 1 12 Tornillo M6x1 0x10 4 13 Válvula de drenaje D 1403 1 14 Pata de caucho Tanque 3 15 Cable interruptor de presión a interruptor de corriente FP209523AV 1 16 Cordón de alimentación 1 17 Tornillo M3x10 1 18 Ensamblaje de bomba motor incluye pieza No 21 FP209039AV 1 19 Cubierta del motor 1 20 Sujetador del cable FP202823AV 1 21 Kit...

Страница 24: ...ncia que no afecten el funcionamiento del compresor d Tanques oxidados incluyendo pero no limitado al óxido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran artículos sujetos a desgaste normal y no son cubiertas después del primer año de propiedad Motor eléctrico válvula de retención interruptor de presión regulador manómetros mangueras tubería...