Series CS Rotary Screw Compressors
www.campbellhausfeld.com
11
Installation (Continued)
Figure 7 - Oil Level
Oil Plug
Maximum
(cold oil level)
Minimum
(cold oil level)
Figure 8 - Control Panel
Power Indicator
(WHITE)
Temperature
Gauge
High Temperature /
High Pressure
Indicator Light
and Reset (RED)
E-Stop
Hour Meter
ON / OFF Switch
[Lighted when in
ON position (GREEN)]
LUBRICATION
THIS UNIT CONTAINS OIL. Before operating
compressor, check oil level (see Figure 7).
Using any other type of oil may shorten pump
life and result in damage.
Recommended Oil
Single viscosity ISO100 rotary screw compressor oil (Part
number GS903800AV - 1 Gallon Container). Available from
Campbell Hausfeld, please call 1-855-504-5678 for customer
assistance.
Oil Capacity
2.1 gallons
OIL LEVEL
Disconnect, tag and lock out
power source then release all
pressure from the system before attempting to install,
service, relocate or perform any maintenance.
RISK OF BURNS! The unit parts, oil,
and screw plug can be hotter than
175° F (80° C)! Wear personal safety equipment!
With hot oil, the oil level can be approximately
3/4 inch higher than with cold oil shortly after
discharging.
An important factor for the operating safety of the compressor
system is the oil level in the oil reservoir. The oil level check must
be performed before initial operation of the compressor and
then repeated every 100 operating hours.