Operating Instructions and Parts Manual  

FP209800

© 2010 Campbell Hausfeld/Scott Fetzer

Oilless 

Compressors

Description

Oilless compressors are designed for 
do-it-yourselfers with a variety of 
home and automotive jobs. These units 
operate without oil. Compressed air 
from this unit will contain moisture. 
Install a water filter or air dryer if 
application requires dry air.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates an  

  imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 

Warning indicates a  

  potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates a  

  potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates  

  important 

information, that if not followed, may 
cause damage to equipment.

Unpacking

After unpacking the unit, inspect 
carefully for any damage that may 
have occurred during transit. Make sure 
to tighten fittings, bolts, etc., before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance.

1.  Read all manuals included 

with this product 
carefully. Be thoroughly 
familiar with the controls 
and the proper use of the 
equipment.

2.  Follow all local electrical and 

safety codes as well as in the US, 
National Electrical Codes (NEC) and 
Occupational Safety and Health Act 
(OSHA).

Have the date code, model number, 
and parts list (with missing parts circled 
before calling.)

 

Do not operate unit  

  if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage.

General Safety Information

CalIFOrnIa PrOPOSItIOn 65

 

This product or  

  its power cord may 

contain chemicals known to the State 
of California to cause cancer and birth 
defects or other reproductive harm. 
Wash hands after handling.

General SaFety InFOrMatIOn

Since the air compressor and other 
components used (filters, lubricators, 
hoses, etc.), make up a high pressure 
pumping system, the following safety 
precautions must be observed at all 
times:

STOP!

Record the Model No., Serial No. and date 
of purchase located on the base below the 
pump in the space below.
Model No.  _______________________
Date Code  _______________________
Date of purchase  _________________

Retain these numbers for future reference.

DO nOt retUrn the 

PrODUCt tO the 

retaIler! Call 
1-800-543-6400

MANUAL

Breathable Air Warning

This compressor/pump is not 
equipped and should not be used “as 
is” to supply breathing quality air. 
For any application of air for human 
consumption, the air compressor/
pump will need to be fitted with 
suitable in-line safety and alarm 
equipment. This additional equip-
ment is necessary to properly filter 
and purify the air to meet minimal 
specifications for Grade D breath-
ing as described in Compressed Gas 
Association Commodity Specification 
G 7.1 - 1966, OSHA 29 CFR 1910. 134, 
and/or Canadian Standards Associa-
tions (CSA).
DISCLAIMER OF WARRANTIES

In the event the compressor is used 
for the purpose of breathing air ap-
plication and proper in-line safety 
and alarm equipment is not simul-
taneously used, existing warranties 
shall be voided, and Campbell Haus-
feld disclaims any liability whatso-
ever for any loss, personal injury or 
damage.

Содержание Attach it to this or file it for safekeeping. IN626701AV

Страница 1: ...nce 1 Read all manuals included with this product carefully Be thoroughly familiar with the controls and the proper use of the equipment 2 Follow all local electrical and safety codes as well as in th...

Страница 2: ...als for proper tightness Motors electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never...

Страница 3: ...Gauges There are two gauges located next to the regulator These gauges read air pressure in pounds per square inch psi The larger gauge shows pressure at the outlet Make sure this gauge reads ZERO by...

Страница 4: ...praying area as hose will allow to prevent over spray from clogging air filter lubrication This is an oilless type compressor requiring no lubrication thermal overload protector This compressor is equ...

Страница 5: ...5 FP209800 www chpower com Notes...

Страница 6: ...urchase unit with higher air delivery SCFM Tank pressure drops when compressor shuts off 1 Open tank drain valve 2 Loose connections fittings tubing air hose any connections etc 3 Tank leaks 1 Close t...

Страница 7: ...re pressure switch to power switch FP209523AV 1 19 Pump motor assembly FP209039AV 1 19a Exhaust tube assembly FP202839AV 1 20 Wire clip FP202823AV 1 21 Screw 1 22 Motor cover t 1 23 5 piece accessory...

Страница 8: ...ustment E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipm...

Страница 9: ...ppeler 1 Lire attentivement tous manuels compris avec ce produit Se familiariser avec ce produit ses commandes et son utilisation 2 Suivre tous les codes de s curit locaux ainsi que les National Elect...

Страница 10: ...servoir Le soudage per age ou autre modifications peuvent affaiblir le r servoir et peuvent r sulter en dommage de rupture ou d explosion Toujours remplacer un r servoir us fendu ou endommag Les pi c...

Страница 11: ...ion d aire la sortie Pour couper le d bit d air tourner le bouton compl tement dans le sens antihoraire Manom tre s Il y a deux types de manom tres pr s du r gulateur Ces manom tres indiquent la press...

Страница 12: ...de s ret se fermera automatiquement environ 276 kPa 345 kPa Si la soupape ne laisse pas sortir l air en tirant sur l anneau ou si elle ne se ferme pas automatiquement il FAUT la remplacer Purger le r...

Страница 13: ...visage 5 Le tuyau doit tre d branch du compresseur et suspendu avec les bouts ouverts face en bas pour laisser couler toute humidit 6 Le compresseur et le tuyau doivent tre rang s dans un endroit frai...

Страница 14: ...on du r servoir tombe lorsque le compresseur s arr te 1 Le robinet de vidange du r servoir est ouvert 2 Raccordements d gag s raccords tuyaux boyaux connexions d air etc 3 Le r servoir pr sente de per...

Страница 15: ...at avec interrupteur FP209523AV 1 19 Montage de pompe moteur FP209039AV 1 19a Trousse de tuyau de ventilation FP202839AV 1 20 Atache de fils FP202823AV 1 21 Vis 1 22 Couvercle de moteur t 1 23 Accesso...

Страница 16: ...ints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un m...

Страница 17: ...rales de Seguridad Como el compresor de aire y otros componentes usados filtros lubricadores mangueras etc forman parte de un sistema de bombeo de alta presi n deber seguir las siguientes medidas de s...

Страница 18: ...para cerciorarse de que est n bien apretadas Los motores equipos el ctricos y controles pueden ocasionar arcos el ctricos que pueden encender gases o vapores inflamables Nunca opere o repare el compr...

Страница 19: ...ente en sentido antihorario el suministro de aire se cierra completamente Man metros Hay dos tipos de man metros ubicados cerca del regulador Estos man metros indican la presi n de aire en libras por...

Страница 20: ...ue el compresor y libere toda la presi n despu s Abra la llave de drenaje ubicada debajo del tanque para drenarle toda la humedad Figura 6 Limpieza APAGUE la unidad y limpie la tapa del cabezal el tan...

Страница 21: ...21 Sp FP209800 Notas...

Страница 22: ...M La presi n del tanque disminuye cuando se apaga el compresor 1 La v lvula de drenaje del tanque est abierta 2 Conexiones flojas accesorios tuber a manguera de aire cualquier conexi n etc 3 Fugas del...

Страница 23: ...ble interruptor de presi n a interruptor de corriente FP209523AV 1 19 Ensamblaje de bomba motor FP209039AV 1 19a Tubo de escape FP202839AV 1 20 Sujetador del cable FP202823AV 1 21 Tornillo 1 22 Cubier...

Страница 24: ...ales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las...