Feed:
This setting is used to feed pellets to the burner and should
only be used in the following scenarios:
1. The first time you use the grill to fill the auger tube.
2. Anytime you inadvertently run the hopper out of pellets or
if you want to change pellet variety.
Once the FEED cycle has finished, the controller will return to
the main menu and the auger tube will be filled with pellets.
You are now ready to start cooking.
Do not over-fire the grill by over feeding pellets into the
burner prior to startup. If flame is inadvertently extinguished
never restart the grill without first cleaning out the burner.
Improper use can cause an uncontrolled fire.
Shutdown:
Use this setting when you are finished with your cook. The
fan will remain on for up to 20 minutes. This setting will burn
up any extra pellets in the burner and cool down the grill.
After 20 minutes the display screen will turn off and the grill
can be unplugged.
This setting must be used after each use.
Do not turn the main power switch off when the grill is hot.
In event of a grease fire, do not use the shutdown mode.
Turn the grill off and use a fire extinguisher.