![Camille Bauer SINEAX AM2000 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/camille-bauer/sineax-am2000/sineax-am2000_device-handbook_3665442007.webp)
7/62 Device handbook SINEAX AM2000, 173 849, 04/2015
4. Mechanical mounting
► The AM2000 is designed for panel mounting
Please ensure that the operating temperature limits are not exceeded when
determining the place of mounting (place of measurement):
-10 ... 55°C
4.1 Panel cutout
Dimensional drawing AM2000:
See section 10
4.2 Mounting of the device
The device is suitable for panel widths up to 8mm.
a) Slide the device into the cutout from
the outside
b) From the side slide in the mounting
clamps into the intended openings and
pull them back about 2 mm
c) Tighten the fixation screws until the
device is tightly fixed with the panel
4.3 Demounting of the device
The demounting of the device may be performed only if all connected wires are out of service. Remove
all plug-in terminals and all connections of the current and voltage inputs. Pay attention to the fact, that
current transformers must be shortened before removing the current connections to the device. Then
demount the device in the opposite order of mounting (4.2).