6.4.6 Resetting the communication settings of the CU5000
If the communication settings of the Standard
interface are no longer known, they can be
reset to the default settings by pressing the
sunk-in reset button (located below the
operating LED) for at least 3s. During the reset
the operating LED flashes red. After the reset
the device is rebooted.
6.5 Protection against device data changing
Configuration or measurement data stored in the device may be modified via either service or settings
menu. To protect these data a security system may be activated (default: not activated). If the security
system is active the user hat to enter a password before executing protected functions. Subsequent to a
successful password input the access remains open until the user leaves the settings / service menu or
an input timeout occurs.
For activating the security system a password input is required. The factory default is: “1234”.
The password can be modified by the user. Permitted characters are ‘a‘…‘z‘,
‘A‘…‘Z‘ and ‘0‘…‘9‘, length 4…12 characters.
ATTENTION
: A reset to factory default will reset also the password. But for a factory
reset the present password needs to be entered. If this password is no longer known
the device must be sent back to the factory!