QUICK mode
The fan motor runs circularly by Turbo setting 4-3 every 1 minute and the LED light changes
synchronously, after 30 minutes the fan switches to AUTO mode and AUTO LED lights up synchronous-
ly. Speed ( ) key can switch speed 1-4 (from low to high) to TURBO.
Filter replacement reset.
PRE filter cleaning/ VOC filter replacement/ FINAL filter replacement
Filter timing reset: passive reset and active reset.
In the normal operation, the filter replacement indicator is turned off. When you accidentally turn on a
light, It will turn off automatically after 5 seconds. Or press ( ) to switch into the three lights off, it
will not affect the timing.
Passive reset: When the machine detects that the filter needs to be cleaned or replaced, The filter LED
will blink continuously to remind users to clean or replace the filter. After users clean or replace the
filter , press ( ) key to switch to the specified filter, activating the corresponding indicator light for
constant brightness. Then press the ( ) key again 3 seconds to reset the timer. If users don’t reset,
LED blinks continuously after 5 seconds.
Active reset: If users think the filter is dirty and want to replace it in advance. Press ( ) key to select
the filter which you want to replace (the filter indicator lights up), press ( ) key for 3 seconds to
reset the timer after replacing filter.
Intensity control
Press ( ) key to set the brightness of the LED in the state of power-on. The setting value is
permanent memory. It still remembers the last brightness when you restart.
4 grades: ( ) high brightness
→
( ) normal brightness ( initial value )
→
( ) half brightness
→
off (air quality lights off, logo LED off, the remaining panel lights are halved in brightness).
Child lock
Press ( ) key for 3 seconds in the state of power-on to open the child lock function. Press the ( )
button for 3 seconds again to unlock the child lock. In the child lock state, only press the ( ) for 3
seconds to unlock, the other key operations are invalid.
Timer setting
Press TIMER ( ) key for regular shutdown, you can set automatic shutdown at 2H, 4H, 8H, 10H,
12H. If the indicator goes out, then the timer setting is cancelled.
Touch
Содержание City Touch