15
IOM-WKM-BALL-370D5
DISTRIBUTED VALVES
TC9186
11. Replace four (4) evenly spaced body nuts on each closure. Tighten these nuts, re-
place all body nuts. Tighten all body nuts.
12. Turn valve assembly upright.
13. The stem and gland plate are installed in the valve as a unit.
a. Install the lower and upper stem O-rings with assembly grease.
b. Install the gland bushing.
Securely block the stem vertically. If available, set in a press.
Lubricate the stem O-ring area.
D I S T R I B U T E D V A L V E S
Installation, Operation and Maintenance Manual
9
W-K-M 370D5
12.
Replace four (4) evenly spaced body nuts on each
closure. Tighten these nuts, replace all body nuts.
Tighten all body nuts.
13.
Turn valve assembly upright.
Set the thrust washer on the stem shoulder.
Set the gland plate on the stem.
Orient the gland plate to the key slot witness mark.
Set the adapter plate on the gland plate.
Firmly press the adaptor plate until the gland plate
and thrust washer make contact with the stem
shoulder.
Set the adapter plate off to one side.
15.
Install the gland plate O-Ring with grease.
Inspect the gland plate O-Ring groove in the body.
Grease the O-Ring groove.
16.
Insert the stem/gland plate unit into the body.
Align the stem pins and key. If the ball is closed,
the keyway should be over the nameplate.
If the ball is open, the keyway should face the
right side of the valve.
Secure the gland plate capscrews. (Refer to
torque table, Part VI, Page 12).
14. The stem and gland plate are installed in the valve
as a unit.
a.
Install the lower and upper stem O-Rings with
assembly grease.
b.
Install the gland bushing.
Securely block the stem vertically. If available, set in
a press.
Lubricate the stem O-Ring area.
17.
Install vent plug assembly.
18.
Finish tightening body nuts with wrench evenly all
around. (Refer to torque table, Part VI, Page 12).
19.
Replace gland plate gasket.
D I S T R I B U T E D V A L V E S
Installation, Operation and Maintenance Manual
9
W-K-M 370D5
12.
Replace four (4) evenly spaced body nuts on each
closure. Tighten these nuts, replace all body nuts.
Tighten all body nuts.
13.
Turn valve assembly upright.
Set the thrust washer on the stem shoulder.
Set the gland plate on the stem.
Orient the gland plate to the key slot witness mark.
Set the adapter plate on the gland plate.
Firmly press the adaptor plate until the gland plate
and thrust washer make contact with the stem
shoulder.
Set the adapter plate off to one side.
15.
Install the gland plate O-Ring with grease.
Inspect the gland plate O-Ring groove in the body.
Grease the O-Ring groove.
16.
Insert the stem/gland plate unit into the body.
Align the stem pins and key. If the ball is closed,
the keyway should be over the nameplate.
If the ball is open, the keyway should face the
right side of the valve.
Secure the gland plate capscrews. (Refer to
torque table, Part VI, Page 12).
14. The stem and gland plate are installed in the valve
as a unit.
a.
Install the lower and upper stem O-Rings with
assembly grease.
b.
Install the gland bushing.
Securely block the stem vertically. If available, set in
a press.
Lubricate the stem O-Ring area.
17.
Install vent plug assembly.
18.
Finish tightening body nuts with wrench evenly all
around. (Refer to torque table, Part VI, Page 12).
19.
Replace gland plate gasket.
D I S T R I B U T E D V A L V E S
Installation, Operation and Maintenance Manual
9
W-K-M 370D5
12.
Replace four (4) evenly spaced body nuts on each
closure. Tighten these nuts, replace all body nuts.
Tighten all body nuts.
13.
Turn valve assembly upright.
Set the thrust washer on the stem shoulder.
Set the gland plate on the stem.
Orient the gland plate to the key slot witness mark.
Set the adapter plate on the gland plate.
Firmly press the adaptor plate until the gland plate
and thrust washer make contact with the stem
shoulder.
Set the adapter plate off to one side.
15.
Install the gland plate O-Ring with grease.
Inspect the gland plate O-Ring groove in the body.
Grease the O-Ring groove.
16.
Insert the stem/gland plate unit into the body.
Align the stem pins and key. If the ball is closed,
the keyway should be over the nameplate.
If the ball is open, the keyway should face the
right side of the valve.
Secure the gland plate capscrews. (Refer to
torque table, Part VI, Page 12).
14. The stem and gland plate are installed in the valve
as a unit.
a.
Install the lower and upper stem O-Rings with
assembly grease.
b.
Install the gland bushing.
Securely block the stem vertically. If available, set in
a press.
Lubricate the stem O-Ring area.
17.
Install vent plug assembly.
18.
Finish tightening body nuts with wrench evenly all
around. (Refer to torque table, Part VI, Page 12).
19.
Replace gland plate gasket.