22
Section 2
MC-III™ EXP Flow Analyzer
Turbine Flowmeter (TFM) Input
The TFM input provides the turbine flowmeter input signal generated by a magnetic pickup, enabling the MC-
III EXP to calculate and display instantaneous flow rates and accumulated totals.
6-3
0 V
DC
TB1
PU
LS
E
IN
PU
T
RE
SE
T
IN
PU
T
TF
M
A&S
GND
TB
3
EXT POWER
TURBINE
MAGNETIC PICKUP
V
MAX
= 3.9 V
J1
J2
RESET
SWITCH
BA
TT
ER
Y
A
B
Figure 2.9—Flowmeter input wiring
Pulse Input
The pulse input provides an optically isolated input in systems where a preamplifier is inserted between the
sensor and the MC-III EXP.
TB
3
TB1
PU
LS
E
IN
PU
T
RE
SE
T
IN
PU
T
TF
M
A&S
GND
EXT POWER
6-3
0 V
DC
J1
J2
RESET
SWITCH
BA
TT
ER
Y
PULSE INPUT
3 TO 30 VDC
Figure 2.10—Pulse input wiring
Содержание NUFLO MC-III EXP
Страница 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Страница 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Страница 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Страница 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Страница 61: ...55 MC III EXP Flow Analyzer Section 4 Configuration Submenus cont d Pulse Output Flow Archive Event Archive ...
Страница 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Страница 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Страница 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Страница 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Страница 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Страница 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Страница 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Страница 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Страница 143: ......